Skip to content
Skillpedia
Security5.8k Β· #14670

auditing-part11-trails

What it does

This skill builds and checks the audit trails that regulated clinical and trial pipelines need, showing who did what, when, and whether the record was changed. It is for teams running processing in FDA-regulated settings such as clinical trials.

When to use it

  • βœ“When an OpenMed pipeline runs in a regulated or validated environment and each action must be recorded.
  • βœ“When a processing step needs an electronic signature with its meaning, signer and timestamp.
  • βœ“When you must check that a stored audit trail has not been changed.

Skill link

https://github.com/maziyarpanahi/openmed/blob/master/skills/auditing-part11-trails/SKILL.md

Copy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.

How to use

The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.

Ready-to-paste message

Use this skill to help me: https://github.com/maziyarpanahi/openmed/blob/master/skills/auditing-part11-trails/SKILL.md Read the SKILL.md file at that link and follow its instructions for my task.
Want your AI to find skills like this on its own?Install the free Skillpedia MCP: one line, and it searches 15,000+ skills before each task.Install in 1 minute β†’

Example of what to ask your AI

β€œOur trial pipeline must keep an audit trail that meets 21 CFR Part 11. Set it up so each run records who ran it and when, with tamper-evident signatures.”

5 new skills a week. 1 minute to read.

How it works

The agent wraps the de-identification audit report with attribution, timestamp and signature details, and provides a way to verify the stored trail later.

Technical content (original SKILL.md)

Original text by the author, straight from GitHub.

Auditing 21 CFR Part 11 trails for OpenMed pipelines

In FDA-regulated GxP work (GCP clinical trials, GLP, GMP) any electronic record used to support a regulatory decision must meet 21 CFR Part 11: it has to be attributable (who), contemporaneous and time-stamped (when), describe what changed, be tamper-evident, and β€” where a signing event occurs β€” carry a controlled electronic signature. These map onto the ALCOA+ data-integrity expectations (Attributable, Legible, Contemporaneous, Original, Accurate, +Complete/Consistent/Enduring/Available).

OpenMed's deidentify(..., audit=True) already emits a deterministic, PHI-free AuditReport that you can .sign() (HMAC-SHA256) and later .verify(). That gives you the tamper-evidence and attribution primitives; this skill wraps them in the who/when/what/e-signature envelope Part 11 wants.

This is a compliance-enablement aid. Part 11 compliance also requires validated systems (CSV), SOPs, and access controls that live outside any single library β€” a QA/validation lead signs off.

When to use

  • OpenMed runs inside a validated/GxP environment and each run must leave an attributable, tamper-evident record.
  • You need to wrap an OpenMed AuditReport with who/when/what + an e-signature manifestation (meaning, signer, timestamp).
  • You must verify a stored trail hasn't been altered, or produce CSV evidence for an inspection.

How OpenMed's AuditReport maps to Part 11

Part 11 expectation 21 CFR cite OpenMed mechanism
Tamper-evident, accurate copies 11.10(b),(c) AuditReport.to_json() + repro_hash over the canonical payload
Audit trail: what changed, when 11.10(e) AuditReport.spans (action per identifier), input_hash/deidentified_text_hash, openmed_version, manifest_hash
Operational/authority checks; attribution 11.10(d),(g) AuditSignature.key_id (signer/key identity) + your envelope's user id
Signature manifestation (name, date, meaning) 11.50 Your envelope fields signer, signed_at, meaning
Signature/record linking, non-repudiation 11.70, 11.200 HMAC-SHA256 over the canonical payload via .sign() / .verify()

The HMAC binds the signature to that exact report content: any later edit to a span, hash, or field changes repro_hash, so .verify() fails β€” that is the tamper-evidence.

Quick start

import openmed, json, datetime as dt

note = "Subject S-014 (DOB 1962-08-09) reported headache on 2024-05-01."

# 1) Produce the deterministic, PHI-free audit record for this processing step.
report = openmed.deidentify(note, policy="hipaa_safe_harbor", audit=True)

# 2) Sign it with a controlled release key (stored in a vault / HSM, never in code).
report.sign(b"<release-hmac-key>", key_id="omv-signer-2026")

# 3) Wrap in a Part 11 envelope: who / when / what / signature meaning.
trail = {
    "record": report.to_dict(),              # tamper-evident, no PHI
    "who": "j.smith@sponsor.example",        # authenticated user (your IdP)
    "when": dt.datetime.now(dt.timezone.utc).isoformat(),
    "what": "PHI de-identification of source narrative (study X, subject S-014)",
    "signature_manifestation": {             # 21 CFR 11.50
        "signer_printed_name": "Jane Smith",
        "meaning": "reviewed and approved",
        "signed_at": dt.datetime.now(dt.timezone.utc).isoformat(),
    },
    "system": {"openmed_version": report.openmed_version,
               "manifest_hash": report.manifest_hash},
}
with open("part11_trail.json", "w") as fh:
    json.dump(trail, fh, indent=2, sort_keys=True)

# 4) Later β€” verify integrity (optionally bind to the exact source/output text).
ok = report.verify(b"<release-hmac-key>", original_text=note)
assert ok, "AUDIT TRAIL TAMPERED OR KEY MISMATCH"

Workflow

  1. Authenticate the actor in your own IdP/access system (Part 11 needs unique IDs and operational checks β€” outside the library). Capture the user id.
  2. Run the processing step with audit=True to get the deterministic record.
  3. Sign with a controlled release key from a vault/HSM; record key_id. Never embed the key in source or the trail.
  4. Build the Part 11 envelope β€” who, when (UTC, contemporaneous), what, and the signature manifestation (printed name, meaning, timestamp) per 11.50.
  5. Append, never overwrite. Store trails write-once (WORM / append-only store). The audit t
FAQ

Does this make my system compliant by itself?

No. Part 11 compliance also needs validated systems, procedures and access controls, which a quality lead must sign off.

What standard do the records follow?

The records are designed around ALCOA+ data integrity principles, such as being attributable and contemporaneous.

Does it need an electronic signature?

Only where a signing event happens. The skill covers those signature details when they apply.

Details

Original description by the author

Generates and verifies 21 CFR Part 11-style audit trails β€” who/what/when, electronic signatures, and tamper-evidence β€” for OpenMed pipelines in GxP and clinical-trial (GCP) settings. Use when the user runs OpenMed in a regulated/validated environment and needs an attributable, time-stamped, tamper-evident record of each processing action, electronic-signature manifestations, or computer-system-validation (CSV) evidence. Trigger keywords: 21 CFR Part 11, Part 11, audit trail, electronic signature, e-signature, GxP, GCP, GLP, GMP, CSV, computer system validation, data integrity, ALCOA, tamper-ev

repo: maziyarpanahi/openmed

Popularity

GitHub stars
5.8k
Ranking position
#14670
License
Apache-2.0
Updated
11/2/2026

Is this skill useful?

0

Sign in to vote.

Comments

  • …

More skills from this repository

Similar skills