Skip to content
Skillpedia
Security5.8k · #14681

checking-hipaa-compliance

What it does

This skill reviews a data pipeline against HIPAA privacy and security requirements before it processes patient information. It is for teams preparing to handle protected health information who need a clear list of gaps.

When to use it

  • ✓When a pipeline is about to process protected health information and needs a pre-deployment review.
  • ✓When you must document administrative, physical and technical safeguards for an audit or security questionnaire.
  • ✓When you need to decide between Safe Harbor and Expert Determination for de-identification.

Skill link

https://github.com/maziyarpanahi/openmed/blob/master/skills/checking-hipaa-compliance/SKILL.md

Copy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.

How to use

The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.

Ready-to-paste message

Use this skill to help me: https://github.com/maziyarpanahi/openmed/blob/master/skills/checking-hipaa-compliance/SKILL.md Read the SKILL.md file at that link and follow its instructions for my task.
Want your AI to find skills like this on its own?Install the free Skillpedia MCP: one line, and it searches 15,000+ skills before each task.Install in 1 minute →

Example of what to ask your AI

“Before we run our notes pipeline on real patient data, check it against the HIPAA requirements and list the gaps.”

5 new skills a week. 1 minute to read.

How it works

The agent walks the pipeline through the safeguard checklist and maps each requirement to what is in place, producing a report of met controls and missing ones.

Technical content (original SKILL.md)

Original text by the author, straight from GitHub.

Checking HIPAA compliance before deploying on PHI

Before any pipeline touches protected health information (PHI), the operating entity (a covered entity or its business associate) must have the HIPAA Privacy Rule and Security Rule safeguards in place. This skill walks a concrete pipeline against those requirements and emits a gap report: which controls are met, which are missing, and where OpenMed's on-device de-identification and signed audit trail satisfy a requirement.

The full control list — administrative, physical, and technical safeguards with their 45 CFR citations — is in references/hipaa-checklist.md. This skill is a self-assessment aid, not legal advice; a Privacy Officer signs off on compliance.

When to use

  • You are about to deploy OpenMed (or any pipeline) on real PHI and need a go/no-go compliance review.
  • You must document safeguards and minimum-necessary controls for an audit, a BAA, or a security questionnaire.
  • You want to decide between Safe Harbor and Expert Determination de-identification and record the rationale.
  • You need a reproducible gap report you can hand to a Privacy/Security Officer.

The two paths to "no longer PHI"

HIPAA recognizes two de-identification methods (45 CFR 164.514):

  1. Safe Harbor — remove all 18 identifier categories and have no actual knowledge the result can re-identify. Deterministic, the common path.
  2. Expert Determination — a qualified statistician certifies "very small" re-identification risk. Used when you must keep some quasi-identifiers.

OpenMed's deidentify(..., policy="hipaa_safe_harbor") targets the Safe Harbor identifier set on-device, and deidentify(..., audit=True) produces a signed, PHI-free AuditReport that documents what was removed — the evidence a Safe Harbor attestation and a Security Rule audit control both want.

Quick start

import openmed

# A representative record from the pipeline (synthetic — never log real PHI).
sample = "John Doe (MRN 1234567), DOB 1970-01-15, seen 2024-03-02 in Boston."

# 1) De-identify on-device under the Safe Harbor policy.
result = openmed.deidentify(sample, method="replace", policy="hipaa_safe_harbor")
print(result.deidentified_text)        # identifiers removed/surrogated

# 2) Produce the signed, no-PHI audit record for the compliance file.
report = openmed.deidentify(sample, policy="hipaa_safe_harbor", audit=True)
report.sign(b"<release-hmac-key-from-vault>", key_id="hipaa-2026")

# 3) Walk the checklist (see references/hipaa-checklist.md) and record gaps.
controls = {
    "encryption_at_rest": True,
    "encryption_in_transit": True,
    "access_controls_rbac": True,
    "audit_logging": True,          # satisfied in part by the signed AuditReport
    "minimum_necessary": False,     # <-- gap: pipeline pulls full notes
    "baa_in_place": True,
    "deidentification_method": "safe_harbor",
}
gaps = [name for name, ok in controls.items() if not ok]
print("GAPS:", gaps)

Workflow

  1. Map the data flow. Diagram every place PHI is created, received, maintained, or transmitted — including model caches, temp files, and logs.
  2. Confirm the legal basis. Is the operator a covered entity or business associate? Is a BAA in place with every downstream vendor that touches PHI? OpenMed running on-device means no third-party processor for the NLP step — note that as a control in your favor.
  3. Run the three safeguard groups from references/hipaa-checklist.md: administrative (risk analysis, workforce training, sanctions), physical (facility/device controls), and technical (access control, audit controls, integrity, transmission security).
  4. Enforce minimum necessary. Pull only the fields the task needs; mask the rest. De-identify as early in the flow as the use case allows.
  5. Record the de-identification method (Safe Harbor vs Expert Determination) and attach the signed AuditReport as evidence.
  6. Emit the gap report — met / not-met / N/A per control, with the 45 CFR citation and the remediation owner. Hand it to the Privacy Officer.

Hand-off to / from OpenMed

  • De-identification: deidentifying-clinical-text (openmed.deidentify, policy="hipaa_safe_harbor") is the technical control that converts PHI to non-PHI on-device — the heart of a HIPAA pipeline.
  • **Identifier coverage:
FAQ

Is this legal advice?

No. It is a self-assessment aid, and a Privacy Officer signs off on compliance.

What are the two ways to make data no longer PHI?

Safe Harbor removes 18 identifier categories, and Expert Determination relies on an expert's assessment of re-identification risk.

Does it cover on-device processing?

Yes. It notes where on-device de-identification and a signed audit trail satisfy a requirement.

Details

Original description by the author

Runs a HIPAA Privacy and Security Rule checklist over a data pipeline and produces a gap report before deploying OpenMed on PHI. Use when the user is about to process protected health information, needs a pre-deployment compliance review, wants to know which administrative, physical, and technical safeguards apply, is scoping a Business Associate Agreement, or must document minimum-necessary and de-identification controls. Trigger keywords: HIPAA, Privacy Rule, Security Rule, 45 CFR 164, PHI, BAA, business associate, minimum necessary, safeguards, Safe Harbor, Expert Determination, gap analysi

repo: maziyarpanahi/openmed

Popularity

GitHub stars
5.8k
Ranking position
#14681
License
Apache-2.0
Updated
11/2/2026

Is this skill useful?

0

Sign in to vote.

Comments

  • …

More skills from this repository

Similar skills