Skip to content
Skillpedia
Databases5.8k Β· #14697

exporting-to-fhir

What it does

This skill turns clinical findings from notes into FHIR R4 health resources, such as Condition and MedicationStatement, with coded concepts attached. It is for developers building exports for electronic health record systems.

When to use it

  • βœ“When clinical findings must be sent to an EHR or FHIR system as structured resources.
  • βœ“When you need a coded concept, such as an RxNorm, LOINC, ICD-10 or SNOMED code.
  • βœ“When you want Condition, MedicationStatement or Observation resources built from NER output.

Skill link

https://github.com/maziyarpanahi/openmed/blob/master/skills/exporting-to-fhir/SKILL.md

Copy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.

How to use

The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.

Ready-to-paste message

Use this skill to help me: https://github.com/maziyarpanahi/openmed/blob/master/skills/exporting-to-fhir/SKILL.md Read the SKILL.md file at that link and follow its instructions for my task.
Want your AI to find skills like this on its own?Install the free Skillpedia MCP: one line, and it searches 15,000+ skills before each task.Install in 1 minute β†’

Example of what to ask your AI

β€œTurn the diagnoses and medications from this note into FHIR Condition and MedicationStatement resources with codes.”

5 new skills a week. 1 minute to read.

How it works

The agent uses OpenMed's helpers to build the coded concepts and resource structure, while you supply the clinical mapping of which finding becomes which resource.

Technical content (original SKILL.md)

Original text by the author, straight from GitHub.

Exporting to FHIR

OpenMed's NER (openmed.analyze_text) returns spans β€” text, label, offsets, confidence. To make those spans interoperable you wrap each clinically relevant span in a FHIR R4 resource (Condition, MedicationStatement, Observation, ...) carrying a coded CodeableConcept. OpenMed ships the mechanical R4 export helpers for this in openmed.clinical.exporters; you own the small amount of clinical mapping (which span becomes which resource).

When to use

Use this after NER, when the consumer is a FHIR system (an EHR, a registry, a data lake on FHIR). Reach for it when the user says "export to FHIR", "make a Condition/Observation", "build a CodeableConcept", or needs RxNorm/LOINC/ICD-10/ SNOMED-coded resources. For packaging many resources into one transaction Bundle, hand off to assembling-fhir-bundles. To check the result against US Core, hand off to validating-us-core.

What OpenMed gives you (verified API)

OpenMed deliberately ships the purely mechanical pieces and leaves clinical judgement to you. The verified entry points:

# CodeableConcept builder β€” openmed/clinical/exporters/codeable_concept_simple.py
from openmed.clinical.exporters.codeable_concept_simple import (
    system_uri,        # vocab id -> canonical HL7 system URI
    coding,            # (system, code, display) -> Coding dict
    codeable_concept,  # [Coding, ...] -> CodeableConcept dict (deterministic order)
)

# Bundle + reference + OperationOutcome β€” openmed/clinical/exporters/fhir/
from openmed.clinical.exporters.fhir import (
    to_bundle,                 # [resource, ...] -> R4 transaction Bundle
    deterministic_fullurl,     # (doc_id, index) -> stable urn:uuid
    OperationOutcomeIssue,     # issue dataclass
    to_operation_outcome,      # [issue, ...] -> OperationOutcome
    from_validation_result,    # validator result -> OperationOutcome
)

system_uri knows these vocabularies out of the box: rxnorm, icd-10-cm, loinc, snomed, hpo, mesh (and passes through any http(s):// URI unchanged). It is the single source of truth for vocab-id β†’ system-URI mapping.

There is no to_condition() / to_observation() magic function. You build the resource shell (a small dict) and drop a codeable_concept(...) into its coded slot. That is by design: the resource type and clinical status are decisions OpenMed will not make for you.

Quick start: entity β†’ Condition

import openmed
from openmed.clinical.exporters.codeable_concept_simple import coding, codeable_concept

# 1) NER (synthetic note β€” no real PHI)
result = openmed.analyze_text(
    "Assessment: type 2 diabetes mellitus, stable.",
    model_name="disease_detection_superclinical",
)
# result.entities -> EntityPrediction(text, label, confidence, start, end)
span = result.entities[0]            # e.g. text="type 2 diabetes mellitus"

# 2) Ground to a code OUT OF PROCESS (your terminology server / mapping table).
#    OpenMed bundles no restricted vocab β€” see querying-terminology-service.
icd_code, snomed_code = "E11.9", "44054006"

# 3) Build the CodeableConcept with OpenMed's builder
cc = codeable_concept(
    [
        coding("snomed", snomed_code, "Diabetes mellitus type 2"),
        coding("icd-10-cm", icd_code, "Type 2 diabetes mellitus without complications"),
    ],
    text=span.text,
)

# 4) Assemble the resource shell yourself
condition = {
    "resourceType": "Condition",
    "id": "cond-1",
    "clinicalStatus": {
        "coding": [{
            "system": "http://terminology.hl7.org/CodeSystem/condition-clinical",
            "code": "active",
        }]
    },
    "verificationStatus": {
        "coding": [{
            "system": "http://terminology.hl7.org/CodeSystem/condition-ver-status",
            "code": "confirmed",
        }]
    },
    "category": [{
        "coding": [{
            "system": "http://terminology.hl7.org/CodeSystem/condition-category",
            "code": "encounter-diagnosis",
        }]
    }],
    "code": cc,                                  # OpenMed-built CodeableConcept
    "subject": {"reference": "Patient/patient-1"},
    "recordedDate": "2024-03-02",
}

codeable_concept sorts codings deterministically (SNOMED, LOINC, RxNorm, ICD-10-CM, HPO, MeSH first; everything else alphabetical), so the JSON is byte-stable across runs β€” important for diffable pipelines and golden tests.

Worked: the resulting Condition.code

{
  "code": {
    "codi
FAQ

Does it choose the codes for me?

The skill provides the mechanical builders. You approve the terminology codes and the clinical mapping.

What if I need many resources in one upload?

A separate bundling skill packages them into one transaction Bundle.

Does it check the result against US Core?

That check is handed to a separate validation skill.

Details

Original description by the author

Convert OpenMed NER output (entities from openmed.analyze_text) into FHIR R4 resources β€” Condition, MedicationStatement, Observation β€” using OpenMed's built-in FHIR R4 export helpers in openmed.clinical.exporters. Covers the verified CodeableConcept builder (coding, codeable_concept, system_uri), deterministic fullUrl references, and OperationOutcome reporting. Use after running OpenMed NER when the user wants standards-conformant FHIR JSON, mentions FHIR, Condition/Observation/MedicationStatement, CodeableConcept, RxNorm/LOINC/ICD-10/SNOMED coding, or interoperability with an EHR. Pairs after

repo: maziyarpanahi/openmed

Popularity

GitHub stars
5.8k
Ranking position
#14697
License
Apache-2.0
Updated
11/2/2026

Is this skill useful?