Skip to content
Skillpedia
Research33k Β· #8836

fda-consultant-specialist

What it does

This skill has your agent act like a senior FDA consultant for medical device companies. It is for regulatory and quality teams planning submissions or checking compliance.

When to use it

  • βœ“When you need to choose an FDA submission pathway, such as 510(k), PMA or De Novo.
  • βœ“When you want a quality system compliance check against FDA rules.
  • βœ“When you are assessing cybersecurity or HIPAA needs for a medical device.

Skill link

https://github.com/davila7/claude-code-templates/blob/main/cli-tool/components/skills/enterprise-communication/fda-consultant-specialist/SKILL.md

Copy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.

How to use

The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.

Ready-to-paste message

Use this skill to help me: https://github.com/davila7/claude-code-templates/blob/main/cli-tool/components/skills/enterprise-communication/fda-consultant-specialist/SKILL.md Read the SKILL.md file at that link and follow its instructions for my task.
Want your AI to find skills like this on its own?Install the free Skillpedia MCP: one line, and it searches 15,000+ skills before each task.Install in 1 minute β†’

Example of what to ask your AI

β€œWhich FDA pathway should my new wearable monitor use, and what do I need to prepare first?”

5 new skills a week. 1 minute to read.

How it works

The agent compares the device against classification and submission routes, then lays out the steps, documents and FDA interactions needed, using structured checklists.

Technical content (original SKILL.md)

Original text by the author, straight from GitHub.

Senior FDA Consultant and Specialist

Expert-level FDA regulatory consulting with comprehensive knowledge of medical device regulations, Quality System Regulation (QSR), HIPAA compliance, cybersecurity requirements, and FDA submission pathways.

Core FDA Regulatory Competencies

1. FDA Pathway Analysis and Selection

Provide expert guidance on optimal FDA regulatory pathways ensuring efficient market access and regulatory compliance.

FDA Pathway Decision Framework:

FDA REGULATORY PATHWAY SELECTION
β”œβ”€β”€ Device Classification Determination
β”‚   β”œβ”€β”€ Predicate device identification
β”‚   β”œβ”€β”€ Classification database research
β”‚   β”œβ”€β”€ Classification panel consultation
β”‚   └── De Novo pathway evaluation
β”œβ”€β”€ Submission Pathway Selection
β”‚   β”œβ”€β”€ 510(k) Clearance Assessment
β”‚   β”‚   β”œβ”€β”€ Traditional 510(k)
β”‚   β”‚   β”œβ”€β”€ Special 510(k)
β”‚   β”‚   └── Abbreviated 510(k)
β”‚   β”œβ”€β”€ PMA (Premarket Approval) Evaluation
β”‚   β”‚   β”œβ”€β”€ Original PMA
β”‚   β”‚   β”œβ”€β”€ Panel-track supplement
β”‚   β”‚   └── Real-time supplement
β”‚   └── De Novo Classification Request
β”‚       β”œβ”€β”€ Novel device evaluation
β”‚       β”œβ”€β”€ Risk classification
β”‚       └── Special controls development
└── Pre-submission Strategy
    β”œβ”€β”€ Q-Sub meeting planning
    β”œβ”€β”€ FDA feedback integration
    β”œβ”€β”€ Submission timeline optimization
    └── Risk mitigation planning

2. Quality System Regulation (QSR) 21 CFR 820 Compliance

Ensure comprehensive compliance with FDA Quality System Regulation throughout medical device lifecycle.

QSR Compliance Framework:

  1. Design Controls (21 CFR 820.30)

    • Design planning and procedures
    • Design input requirements and documentation
    • Design output specifications and verification
    • Design review, verification, and validation
    • Design transfer and change control
  2. Management Responsibility (21 CFR 820.20)

    • Quality policy establishment and communication
    • Organizational structure and responsibility
    • Management representative designation
    • Management review process implementation
  3. Document Controls (21 CFR 820.40)

    • Document approval and distribution procedures
    • Document change control processes
    • Document retention and access management
    • Obsolete document control
  4. Corrective and Preventive Actions (21 CFR 820.100)

    • CAPA System Implementation: Follow references/fda-capa-requirements.md
    • Investigation and root cause analysis procedures
    • Corrective action implementation and verification
    • Preventive action identification and implementation

3. FDA Submission Preparation and Management

Lead comprehensive FDA submission preparation ensuring regulatory compliance and approval success.

510(k) Submission Process:

  1. Pre-submission Activities

    • Predicate device analysis and substantial equivalence strategy
    • Q-Sub meeting preparation and FDA consultation
    • Testing strategy development and validation
    • Decision Point: Determine submission readiness and pathway confirmation
  2. 510(k) Preparation

    • Device Description: Comprehensive device characterization
    • Indications for Use: Clinical indication and patient population
    • Substantial Equivalence Comparison: Predicate device analysis
    • Performance Testing: Bench testing, biocompatibility, software validation
    • Labeling: Instructions for use and contraindications
  3. FDA Review Management

    • FDA communication and additional information responses
    • Review timeline monitoring and management
    • FDA questions and clarification coordination
    • Clearance letter processing and market launch preparation

PMA Submission Process:

  1. Clinical Investigation Requirements

    • IDE (Investigational Device Exemption) strategy and submission
    • Clinical study protocol development and validation
    • Good Clinical Practice (GCP) compliance oversight
    • Clinical data analysis and statistical evaluation
  2. PMA Application Preparation

    • Manufacturing information and quality system documentation
    • Clinical and nonclinical safety and effectiveness data
    • Risk analysis and benefit-risk assessment
    • Labeling and post-market study commitments

4. HIPAA Compliance and Healthcare Data Protection

Ensure comprehensive HIPAA compliance for medical devices handling protected health information (PHI).

HIPAA Compliance Framework:

HIPAA COMPLIANCE REQUIREMENTS
β”œβ”€β”€ Administrative Safeguards
β”‚   β”œβ”€β”€ Security officer designation
β”‚  
FAQ

Is this official FDA advice?

No. It is expert-style guidance, and you should confirm decisions with FDA resources and qualified regulatory staff.

Which pathways does it cover?

It covers 510(k) clearance, PMA and De Novo, including pre-submission planning.

Does it cover quality system rules?

Yes. It includes the Quality System Regulation, 21 CFR 820, as part of compliance assessments.

Details

Original description by the author

Senior FDA consultant and specialist for medical device companies including HIPAA compliance and requirement management. Provides FDA pathway expertise, QSR compliance, cybersecurity guidance, and regulatory submission support. Use for FDA submission planning, QSR compliance assessments, HIPAA evaluations, and FDA regulatory strategy development.

repo: davila7/claude-code-templates

Popularity

GitHub stars
33k
Ranking position
#8836
License
MIT
Updated
11/2/2026

Is this skill useful?

0

Sign in to vote.

Comments

  • …

More skills from this repository

Similar skills