ics-overview
What it does
This catalog covers testing for industrial control and operational technology networks, such as factory and utility controllers. It is for specialists with written approval, since changes can affect physical processes and people.
When to use it
- βWhen an authorized assessment targets an industrial network with PLCs, HMIs or SCADA systems.
- βWhen a plant or utility wants a read-only inventory of its control devices.
- βWhen a review is considering any write action that could change a physical process.
Skill link
https://github.com/BitterSecurity/Decepticon/blob/main/packages/decepticon/decepticon/skills/standard/ics/SKILL.mdCopy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.
How to use
The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.
Ready-to-paste message
For Claude Code, Codex or Cursor: run it in your project folder and the skill gets installed.
Download the SKILL.md and drop it into your agentβs skills folder.
Example of what to ask your AI
βWe run a water treatment plant. Can you plan a read-only assessment of our control network with the plant operators involved?β
5 new skills a week. 1 minute to read.
How it works
The agent confirms the written scope, starts with read-only discovery, and loads the matching protocol guide only after the safety conditions are met.
Technical content (original SKILL.md)
Original text by the author, straight from GitHub.
ICS / OT Operator Skill Catalog
Industrial engagements are not application security with longer rules of engagement β they are a different discipline. A miswritten Modbus coil on a real plant kills people. This catalog is read-mostly by default; every write-scope skill carries an explicit safety gate.
Hard rules
- No writes without OPPLAN.safety_critical confirmation. The
middleware refuses writes when the active OPPLAN objective does not
carry
safety_critical_confirmed=true. Bypass requires operator signature in/workspace/safety-attestation.txt. - Read-only protocol discovery first. Identify what's on the wire before any active probing. Many ICS protocols are unauthenticated; a single malformed read can crash an old PLC.
- Out-of-band physical safety. The blue team includes plant ops.
A ConOps with
blue_team.plant_ops_phoneis mandatory for engagements on active production lines.
Playbooks
Inline technique reference β not separately loadable skills. The entries below are summarized here for direct use; there is no separate
SKILL.mdto open for each. Do NOT call the skill loader on them β apply the technique with your tools using this summary and the protocol assessment guidance in this file.
| Technique | Use for |
|---|---|
| modbus-discovery | Read-only Modbus TCP/RTU enumeration, function code 3/4 polling |
| modbus-write | GATED Write coils / registers; safety gate enforced |
| bacnet-discovery | BACnet/IP Who-Is, object enumeration, device profile |
| s7comm | Siemens S7 / S7Comm Plus enumeration via Snap7 / python-snap7 |
| dnp3 | DNP3 outstation / master discovery; integrity poll |
| opcua | OPC-UA browse, anonymous auth check, certificate analysis |
| hmi-web | HMI web stacks (Wonderware, Iconics, Schneider) β known CVEs |
| engineering-software | TIA Portal / Studio 5000 / Unity Pro project extraction |
Protocol assessment
- Passive observation: tap a SPAN port if available. Identify protocols
on the wire (
tshark -Y modbus || tshark -Y bacnet || ...). - Network-layer discovery: nmap with
-sV --script modbus-discover,bacnet-info,s7-info,dnp3-info(NSE scripts ship in Kali by default; some are slow β set-T2for production networks). - Function-code-3 polling: read holding registers from every Modbus
device discovered. Log register maps to the knowledge graph as
:Servicenodes withprotocol=modbus. - Identify the safety integrity level (SIL) of any device touched. SIL 3+ devices NEVER get write probes without plant-ops sign-off.
- Engineering software attack path: if you can reach the engineering workstation, extract the project archive (.s7p, .acd, .stp). The project file is the crown jewel β it reveals the entire process model.
Detection gap
ICS networks rarely have host-based detection on PLCs/RTUs themselves β the detection stack lives on the engineering workstation, the historian, and any IT/OT gateway. Relevant Sigma detection patterns include:
- Function-code anomalies (write to coils outside normal ranges).
- Connection sources outside the documented MES/SCADA IP set.
- TIA Portal / Studio 5000 project download events.
Out of scope by default
Active glitching of PLC firmware; firmware upload to PLCs; safety
controller writes β all of these require an explicit RoE annex signed
by the asset owner. The default ICS RoE template in soundwave/ includes
this annex skeleton.
FAQ
Why is the default read-only?
The catalog says a miswritten command can harm a plant, so writes need explicit approval.
Who should be involved?
The catalog says plant operations staff should be part of the plan for active production lines.
Which protocols are covered?
Modbus, BACnet, Siemens S7, DNP3 and OPC UA, among others.
Details
Original description by the author
Use when the target is an industrial control system or operational technology network running Modbus, BACnet, S7Comm/S7Comm Plus, DNP3, OPC-UA, or any PLC/HMI/SCADA stack. Engagements MUST set RoE flag industrial_safety_critical=true; this catalog gates every write-scope operation behind explicit operator confirmation regardless of HITL middleware.
Popularity
- GitHub stars
- 6.5k
- Ranking position
- #14091
- License
- Apache-2.0
- Updated
- 11/1/2026
Comments
- β¦
More skills from this repository
detector-overview
6.5kHelps your agent read code that a scanner flagged and decide which flagged spots are real security bugs and which are false alarms.
exploiter-overview
6.5kHelps your agent join several confirmed security weaknesses into one test chain and check how far that chain could reach.
llm-redteam-overview
6.5kHelps your agent find the right AI red-team guide for a test, covering 15 tactic groups from prompt injection to model abuse.
aatmf-t01-prompt-injection
6.5kExplains prompt injection, where hidden instructions try to override an AI system, so security testers can check for it.
Similar skills
reverse-engineer-anything
422kHelps your agent look inside shipped apps and packages to explain features, compare versions, or guide a rebuild, using the REA tool.
1password
394kHelps your agent set up the 1Password CLI, sign in, and read or inject secrets without printing their values into chat.
healthcheck
394kHelps your agent audit the computer or server that runs OpenClaw for security risks, such as SSH, firewall, updates, and backups, then suggest safe fixes.