Skip to content
Skillpedia
Security6.5k Β· #14091

ics-overview

What it does

This catalog covers testing for industrial control and operational technology networks, such as factory and utility controllers. It is for specialists with written approval, since changes can affect physical processes and people.

When to use it

  • βœ“When an authorized assessment targets an industrial network with PLCs, HMIs or SCADA systems.
  • βœ“When a plant or utility wants a read-only inventory of its control devices.
  • βœ“When a review is considering any write action that could change a physical process.

Skill link

https://github.com/BitterSecurity/Decepticon/blob/main/packages/decepticon/decepticon/skills/standard/ics/SKILL.md

Copy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.

How to use

The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.

Ready-to-paste message

Use this skill to help me: https://github.com/BitterSecurity/Decepticon/blob/main/packages/decepticon/decepticon/skills/standard/ics/SKILL.md Read the SKILL.md file at that link and follow its instructions for my task.
Want your AI to find skills like this on its own?Install the free Skillpedia MCP: one line, and it searches 15,000+ skills before each task.Install in 1 minute β†’

Example of what to ask your AI

β€œWe run a water treatment plant. Can you plan a read-only assessment of our control network with the plant operators involved?”

5 new skills a week. 1 minute to read.

How it works

The agent confirms the written scope, starts with read-only discovery, and loads the matching protocol guide only after the safety conditions are met.

Technical content (original SKILL.md)

Original text by the author, straight from GitHub.

ICS / OT Operator Skill Catalog

Industrial engagements are not application security with longer rules of engagement β€” they are a different discipline. A miswritten Modbus coil on a real plant kills people. This catalog is read-mostly by default; every write-scope skill carries an explicit safety gate.

Hard rules

  1. No writes without OPPLAN.safety_critical confirmation. The middleware refuses writes when the active OPPLAN objective does not carry safety_critical_confirmed=true. Bypass requires operator signature in /workspace/safety-attestation.txt.
  2. Read-only protocol discovery first. Identify what's on the wire before any active probing. Many ICS protocols are unauthenticated; a single malformed read can crash an old PLC.
  3. Out-of-band physical safety. The blue team includes plant ops. A ConOps with blue_team.plant_ops_phone is mandatory for engagements on active production lines.

Playbooks

Inline technique reference β€” not separately loadable skills. The entries below are summarized here for direct use; there is no separate SKILL.md to open for each. Do NOT call the skill loader on them β€” apply the technique with your tools using this summary and the protocol assessment guidance in this file.

Technique Use for
modbus-discovery Read-only Modbus TCP/RTU enumeration, function code 3/4 polling
modbus-write GATED Write coils / registers; safety gate enforced
bacnet-discovery BACnet/IP Who-Is, object enumeration, device profile
s7comm Siemens S7 / S7Comm Plus enumeration via Snap7 / python-snap7
dnp3 DNP3 outstation / master discovery; integrity poll
opcua OPC-UA browse, anonymous auth check, certificate analysis
hmi-web HMI web stacks (Wonderware, Iconics, Schneider) β€” known CVEs
engineering-software TIA Portal / Studio 5000 / Unity Pro project extraction

Protocol assessment

  1. Passive observation: tap a SPAN port if available. Identify protocols on the wire (tshark -Y modbus || tshark -Y bacnet || ...).
  2. Network-layer discovery: nmap with -sV --script modbus-discover, bacnet-info, s7-info, dnp3-info (NSE scripts ship in Kali by default; some are slow β€” set -T2 for production networks).
  3. Function-code-3 polling: read holding registers from every Modbus device discovered. Log register maps to the knowledge graph as :Service nodes with protocol=modbus.
  4. Identify the safety integrity level (SIL) of any device touched. SIL 3+ devices NEVER get write probes without plant-ops sign-off.
  5. Engineering software attack path: if you can reach the engineering workstation, extract the project archive (.s7p, .acd, .stp). The project file is the crown jewel β€” it reveals the entire process model.

Detection gap

ICS networks rarely have host-based detection on PLCs/RTUs themselves β€” the detection stack lives on the engineering workstation, the historian, and any IT/OT gateway. Relevant Sigma detection patterns include:

  • Function-code anomalies (write to coils outside normal ranges).
  • Connection sources outside the documented MES/SCADA IP set.
  • TIA Portal / Studio 5000 project download events.

Out of scope by default

Active glitching of PLC firmware; firmware upload to PLCs; safety controller writes β€” all of these require an explicit RoE annex signed by the asset owner. The default ICS RoE template in soundwave/ includes this annex skeleton.

FAQ

Why is the default read-only?

The catalog says a miswritten command can harm a plant, so writes need explicit approval.

Who should be involved?

The catalog says plant operations staff should be part of the plan for active production lines.

Which protocols are covered?

Modbus, BACnet, Siemens S7, DNP3 and OPC UA, among others.

Details

Original description by the author

Use when the target is an industrial control system or operational technology network running Modbus, BACnet, S7Comm/S7Comm Plus, DNP3, OPC-UA, or any PLC/HMI/SCADA stack. Engagements MUST set RoE flag industrial_safety_critical=true; this catalog gates every write-scope operation behind explicit operator confirmation regardless of HITL middleware.

repo: BitterSecurity/Decepticon

Popularity

GitHub stars
6.5k
Ranking position
#14091
License
Apache-2.0
Updated
11/1/2026

Is this skill useful?

0

Sign in to vote.

Comments

  • …

More skills from this repository