Skip to content
Skillpedia
Misc29k · #9467

iso13485-audit-prep

What it does

This skill makes the agent act like a strict ISO 13485 auditor for medical device quality systems. It is for quality and regulatory teams preparing for internal audits, regulator reviews or product launches.

When to use it

  • ✓When an internal audit of your medical device quality system is coming up.
  • ✓When you are preparing for an MDR or FDA review of your device records.
  • ✓When a corrective action was closed and you need proof that it actually worked.

Skill link

https://github.com/alirezarezvani/claude-skills/blob/main/compliance-os/skills/iso13485-audit-prep/SKILL.md

Copy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.

How to use

The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.

Ready-to-paste message

Use this skill to help me: https://github.com/alirezarezvani/claude-skills/blob/main/compliance-os/skills/iso13485-audit-prep/SKILL.md Read the SKILL.md file at that link and follow its instructions for my task.
Want your AI to find skills like this on its own?Install the free Skillpedia MCP: one line, and it searches 15,000+ skills before each task.Install in 1 minute →

Example of what to ask your AI

“Can you check our medical device quality records and tell me what an auditor would flag before our internal audit?”

5 new skills a week. 1 minute to read.

How it works

You give the agent a scope, such as one product or process. It then works through six audit questions and points out gaps in design files, corrective actions and traceability.

Technical content (original SKILL.md)

Original text by the author, straight from GitHub.

/compliance-os:iso13485-audit-prep — ISO 13485 QMS Forcing Questions

Command: /compliance-os:iso13485-audit-prep <scope>

The ISO 13485 QMS auditor pressure-tests any medical-device QMS work. Six traceability-obsessed questions before any internal audit, MDR / FDA QSR review, or product launch.

When to Run

  • Before annual Clause 8.2.4 internal audit
  • Before MDR / FDA QSR alignment review (substantially harmonized post Feb 2026)
  • Before new-device commercial launch (DHF closure audit)
  • After significant CAPA closure event (effectiveness verification audit)
  • Post-recall event (root cause + corrective action audit)
  • Quarterly during regulatory submission preparation

The Six QMS Questions

1. Pull three random DHFs. Are design verification + validation evidence complete?

Most-cited finding area.

  • DHF must include: design plan + inputs + outputs + verification + validation + transfer + changes
  • Sample stratified by product class (I, IIa, IIb, III per MDR)
  • Reference iso13485_audit_playbook.md for the per-DHF checklist
  • Verify traceability matrix from user needs through clinical evidence

2. Show me the last 5 CAPAs with effectiveness verification evidence.

Second-most-cited finding area.

  • Containment / correction / corrective action distinction documented
  • Root cause analysis depth: 5 Why minimum
  • Effectiveness verification = measurable evidence, not "we updated the procedure"
  • Closure approved by appropriate authority
  • Repeat CAPAs across products = systemic issue trigger

3. When was process validation (IQ/OQ/PQ) last revalidated?

Clause 7.5.6 — often stale.

  • Initial validation at process introduction
  • Revalidation triggers: process change, equipment change, material change, periodic schedule
  • Trend monitoring (SPC) where statistical techniques apply per Clause 8.4
  • Cross-check with cs-fda-qsr-auditor for 21 CFR 820.75 alignment

4. Show me the risk management file for the highest-risk product.

Clause 7.1 + ISO 14971:2019.

  • Risk management plan exists per product
  • Hazard identification covers reasonable foreseeable misuse
  • Risk control hierarchy applied: inherent safety > protective measures > information for safety
  • Residual risk evaluated + accepted with rationale
  • Post-production information feeds back into RMF
  • For AI-enabled medical devices: layer ISO 42001 A.5 impact assessment on top

5. Show me post-market surveillance evidence — last 6 months.

Clause 8.2.1 — high-stakes for MDR + FDA.

  • Customer complaint log + investigation closure
  • Vigilance reports (serious incident / FSCA) submitted per applicable regulation
  • Trend analysis evidence + management review input
  • Post-market clinical follow-up (PMCF) for MDR high-risk devices
  • MDR reports per 21 CFR 803 for US-marketed devices (cross-check with cs-fda-qsr-auditor)

6. Where's the management review evidence covering all Clause 5.6 inputs?

Annual minimum; semi-annual for mature programs.

  • Required inputs per Clause 5.6.2: audit results, customer feedback, process performance, product conformity, status of preventive + corrective actions, follow-up from prior reviews, changes that could affect QMS, recommendations for improvement, regulatory requirements
  • Outputs per Clause 5.6.3: improvement decisions, product requirement changes, resource needs
  • Integrated review across frameworks (per multi_framework_audit_playbook.md) preferred

Workflow

# 1. Audit programme optimization
python ${CLAUDE_PLUGIN_ROOT}/vendor/ra-qm-team/qms-audit-expert/scripts/audit_schedule_optimizer.py audit_scope.json

# 2. Mock audit for readiness check
python ../../skills/compliance-os/scripts/audit_simulator.py iso13485_scope.json

# 3. CAPA system review
# Route to ${CLAUDE_PLUGIN_ROOT}/vendor/ra-qm-team/capa-officer/ tools

# 4. Risk management file review
# Route to ${CLAUDE_PLUGIN_ROOT}/vendor/ra-qm-team/risk-management-specialist/ tools

Output Format

# ISO 13485 Audit Prep: <scope>
**Date:** YYYY-MM-DD

## The Decision Being Made
[programme-plan | DHF-closure | CAPA-health | post-market-trend | pre-cert | MDR-FDA-alignment]

## Design Control Status (sampled DHFs)
- DHFs sampled: <list product IDs>
- Verification evidence: pass/fail per DHF
- Validation evidence: pass/fail per DHF
- Clinical evidence (per MDR Annex XIV / FDA 510(k)): pass/fail
- Traceability matrix complete: yes/no per DHF

## CAPA Health
- CAPAs sampled: N
- Root cause analysis depth: 
FAQ

Does this skill replace a qualified auditor?

No. It helps you find likely gaps, but a qualified person should still confirm the results against the actual standard.

Which parts of the quality system does it check most closely?

It focuses on design verification and validation evidence and on corrective actions with proof they worked.

What should I give the agent to get useful results?

Give it the scope, such as one product or one process, along with the records you have for it.

Details

Original description by the author

Use for /compliance-os:iso13485-audit-prep, or before an ISO 13485 internal audit or DHF closure.

repo: alirezarezvani/claude-skills

Popularity

GitHub stars
29k
Ranking position
#9467
License
MIT
Updated
11/2/2026

Is this skill useful?

0

Sign in to vote.

Comments

  • …

More skills from this repository

Similar skills