Skip to content
Skillpedia
Misc29k Β· #9735

mdr-745-specialist

What it does

This skill helps medical device makers work through the EU MDR, from classifying a device to finding gaps in its technical file. It is for regulatory and quality staff preparing for notified body review.

When to use it

  • βœ“When you need to classify a medical device under the EU MDR.
  • βœ“When you want to check a technical file for missing documents before a notified body review.
  • βœ“When you need to plan post-market surveillance and periodic safety reporting for a device.

Skill link

https://github.com/alirezarezvani/claude-skills/blob/main/ra-qm-team/skills/mdr-745-specialist/SKILL.md

Copy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.

How to use

The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.

Ready-to-paste message

Use this skill to help me: https://github.com/alirezarezvani/claude-skills/blob/main/ra-qm-team/skills/mdr-745-specialist/SKILL.md Read the SKILL.md file at that link and follow its instructions for my task.
Want your AI to find skills like this on its own?Install the free Skillpedia MCP: one line, and it searches 15,000+ skills before each task.Install in 1 minute β†’

Example of what to ask your AI

β€œCheck our technical file for EU MDR gaps and tell me which Annex II or III items are missing.”

5 new skills a week. 1 minute to read.

How it works

The agent works through the classification rules, reviews the technical file against the requirements, and outlines the clinical evidence and post-market reporting steps. A script checks the file for gaps.

Technical content (original SKILL.md)

Original text by the author, straight from GitHub.

MDR 2017/745 Specialist

EU MDR compliance patterns for medical device classification, technical documentation, and clinical evidence.


Table of Contents


Device Classification Workflow

Classify device under MDR Annex VIII:

  1. Identify device duration (transient, short-term, long-term)
  2. Determine invasiveness level (non-invasive, body orifice, surgical)
  3. Assess body system contact (CNS, cardiac, other)
  4. Check if active device (energy dependent)
  5. Apply classification rules 1-22
  6. For software, apply MDCG 2019-11 algorithm
  7. Document classification rationale
  8. Validation: Classification confirmed with Notified Body

Classification Matrix

Factor Class I Class IIa Class IIb Class III
Duration Any Short-term Long-term Long-term
Invasiveness Non-invasive Body orifice Surgical Implantable
System Any Non-critical Critical organs CNS/cardiac
Risk Lowest Low-medium Medium-high Highest

Software Classification (MDCG 2019-11)

Information Use Condition Severity Class
Informs decision Non-serious IIa
Informs decision Serious IIb
Drives/treats Critical III

Classification Examples

Example 1: Absorbable Surgical Suture

  • Rule 8 (implantable, long-term)
  • Duration: > 30 days (absorbed)
  • Contact: General tissue
  • Classification: Class IIb

Example 2: AI Diagnostic Software

  • Rule 11 + MDCG 2019-11
  • Function: Diagnoses serious condition
  • Classification: Class IIb

Example 3: Cardiac Pacemaker

  • Rule 8 (implantable)
  • Contact: Central circulatory system
  • Classification: Class III

Technical Documentation

Prepare technical file per Annex II and III:

  1. Create device description (variants, accessories, intended purpose)
  2. Develop labeling (Article 13 requirements, IFU)
  3. Document design and manufacturing process
  4. Complete GSPR compliance matrix
  5. Prepare benefit-risk analysis
  6. Compile verification and validation evidence
  7. Integrate risk management file (ISO 14971)
  8. Validation: Technical file reviewed for completeness

Technical File Structure

ANNEX II TECHNICAL DOCUMENTATION
β”œβ”€β”€ Device description and UDI-DI
β”œβ”€β”€ Label and instructions for use
β”œβ”€β”€ Design and manufacturing info
β”œβ”€β”€ GSPR compliance matrix
β”œβ”€β”€ Benefit-risk analysis
β”œβ”€β”€ Verification and validation
└── Clinical evaluation report

GSPR Compliance Checklist

Requirement Evidence Status
Safe design (GSPR 1-3) Risk management file ☐
Chemical properties (GSPR 10.1) Biocompatibility report ☐
Infection risk (GSPR 10.2) Sterilization validation ☐
Software requirements (GSPR 17) IEC 62304 documentation ☐
Labeling (GSPR 23) Label artwork, IFU ☐

Conformity Assessment Routes

Class Route NB Involvement
I Annex II self-declaration None
Is/Im Annex II + IX/XI Sterile/measuring aspects
IIa Annex II + IX or XI Product or QMS
IIb Annex IX, or Annex X + XI QMS + tech doc assessment, or type exam + production
III Annex IX, or Annex X + XI Full QMS + product dossier, or type exam + production

Clinical Evidence

Develop clinical evidence strategy per Annex XIV:

  1. Define clinical claims and endpoints
  2. Conduct systematic literature search
  3. Appraise clinical data quality
  4. Assess equivalence (technical, biological, clinical)
  5. Identify evidence gaps
  6. Determine if clinical investigation required
  7. Prepare Clinical Evaluation Report (CER)
  8. Validation: CER reviewed by qualified evaluator

Evidence Requirements by Class

Class Minimum Evidence Investigation
I Risk-benefit analysis Not typically required
IIa Literature + post-market May be required
IIb Systematic literature review Often required
III Comprehensive clinical data Required (Article 61)

Clinical Evaluation Report Structure

FAQ

How does it decide the device class?

It works through the Annex VIII classification rules, asking about duration, invasiveness, body system contact and whether the device is active.

Is its classification final?

The skill says classification should be confirmed with a notified body, so its result is a starting point.

Does it cover software devices?

Yes. For software, it applies the MDCG 2019-11 algorithm.

Details

Original description by the author

Use for EU MDR 2017/745 work: device classification under Annex VIII, technical file gaps (Annex II/III), clinical evaluation, PMS and PSUR cadence, notified body prep. Checks the file with mdr_gap_analyzer.py.

repo: alirezarezvani/claude-skills

Popularity

GitHub stars
29k
Ranking position
#9735
License
MIT
Updated
11/2/2026

Is this skill useful?

0

Sign in to vote.

Comments

  • …

More skills from this repository

Similar skills