ruview-configure
What it does
This skill guides the AI through changing how a deployed RuView sensing system behaves, without touching code. It covers device settings, firmware options and server flags. It is for people maintaining a working setup.
When to use it
- ✓When you need to change the WiFi network or target address on a deployed sensing node.
- ✓When you want to switch a board to a different firmware variant.
- ✓When you are adding several nodes into one mesh setup.
Skill link
https://github.com/ruvnet/RuView/blob/main/plugins/ruview/skills/ruview-configure/SKILL.mdCopy it and paste it into your AI (Claude, ChatGPT or Cursor), asking it to follow the instructions.
How to use
The easiest way: copy the message and paste it into your AI. It reads the skill and follows the instructions.
Ready-to-paste message
For Claude Code, Codex or Cursor: run it in your project folder and the skill gets installed.
Download the SKILL.md and drop it into your agent’s skills folder.
Example of what to ask your AI
“Change the target IP on my sensing node to our new server without reflashing the firmware.”
5 new skills a week. 1 minute to read.
How it works
The skill explains which settings can be written to the device over serial, which need a firmware rebuild, and which are server flags. The AI uses the provisioning script to change the device settings.
Technical content (original SKILL.md)
Original text by the author, straight from GitHub.
RuView Configuration
Everything you can tune in a RuView deployment, from a one-line provision flag to a full mesh + Cognitum Seed setup.
1. Firmware build-time config (sdkconfig)
| Variant | File | When |
|---|---|---|
| 8MB (default) | firmware/esp32-csi-node/sdkconfig.defaults.template |
ESP32-S3 8MB, full feature set, real WiFi CSI |
| 4MB | firmware/esp32-csi-node/sdkconfig.defaults.4mb |
ESP32-S3 SuperMini 4MB — display disabled, dual OTA slots (partitions_4mb.csv, ~1.856 MB each) |
| Heltec N16R2 | firmware/esp32-csi-node/sdkconfig.defaults.heltec_n16r2 |
Heltec boards |
Switch: cp firmware/esp32-csi-node/sdkconfig.defaults.<variant> firmware/esp32-csi-node/sdkconfig.defaults, then rebuild (see ruview-hardware-setup). Never test in mock mode — the Kconfig fall-threshold bug only showed up with real CSI.
2. Runtime device config (NVS via provision.py)
provision.py writes the csi_cfg NVS namespace over the serial port. Run python firmware/esp32-csi-node/provision.py --help for the authoritative flag list (on Windows force PYTHONUTF8=1 PYTHONIOENCODING=utf-8 — the help text contains non-ASCII and crashes under cp1252).
python firmware/esp32-csi-node/provision.py --port COM8 \
--ssid "WiFi" --password "secret" \
--target-ip 192.168.1.20 --target-port 5005 \ # aggregator UDP sink (port default 5005)
--node-id 1 \ # 0-255
--channel 6 --filter-mac AA:BB:CC:DD:EE:FF # ADR-060: pin channel + filter transmitter
| Flag group | Flags | Notes |
|---|---|---|
| WiFi / sink | --ssid --password --target-ip --target-port (5005) --node-id |
--node-id 0-255 |
| TDM mesh | --tdm-slot --tdm-total |
0-based slot index + total node count — this is how multi-node mesh is slotted |
| Edge processing | --edge-tier {0,1,2} |
0=off, 1=stats, 2=vitals (ADR-041) |
| Detection thresholds | --pres-thresh (50) --fall-thresh (15000 → 15.0 rad/s²) |
raise --fall-thresh to cut false falls in high-traffic areas (issue #263) |
| Vitals | --vital-win (300 frames) --vital-int (1000 ms) --subk-count (32, top-K subcarriers) |
|
| Channel / hopping | --channel (1-14 / 36-177, overrides AP auto-detect) --filter-mac --hop-channels (1,6,11) --hop-dwell (200 ms) |
omit --channel + set --hop-channels for ADR-061 multi-freq hopping; omit --filter-mac to capture all transmitters |
| Cognitum Seed | --seed-url (http://10.1.10.236) --seed-token (Bearer, from pairing) --zone (lobby) |
|
| Swarm | --swarm-hb (30 s) --swarm-ingest (5 s) |
heartbeat + vector ingest intervals |
| Mode | --dry-run (build NVS bin, don't flash) --baud (460800) --force-partial |
⚠️ NVS namespace is replaced wholesale (issue #391). Flashing rewrites the entire
csi_cfgnamespace — any key you don't pass on the CLI is erased. Always pass the full set you want, or use--force-partialknowingly. Read the device's current values off the serial boot log first (adaptive_ctrl/csi_collectorlines) if you're unsure.
- NVS partition images for fleet provisioning:
scripts/generate_nvs_matrix.py(subprocess-first — theesp_idf_nvs_partition_genAPI changed across versions).
3. Sensing server flags
cd v2
cargo run -p wifi-densepose-sensing-server -- --help
# Common modes:
cargo run -p wifi-densepose-sensing-server # live sink, default port
cargo run -p wifi-densepose-sensing-server -- --pretrain --dataset data/csi/ --pretrain-epochs 50
cargo run -p wifi-densepose-sensing-server -- --train --dataset data/mmfi/ --epochs 100 --save-rvf model.rvf
cargo run -p wifi-densepose-sensing-server -- --model model.rvf --embed
cargo run -p wifi-densepose-sensing-server -- --model model.rvf --build-index env
wifiscan server (multi-BSSID, ADR-022): cargo run -p wifi-densepose-sensing-server consumes wifi-densepose-wifiscan output; use neighbour APs as free radar illuminators.
4. Edge intelligence modules (ADR-041)
Small Rust/WASM programs that run on the ESP32 itself — no internet, instant response. See docs/edge-modules/ and docs/adr/ADR-041-*. Each module declares its CSI feature inputs (8-dim feature vectors) and an RVF store target (Cognitum Seed). Configure which modules ship in a build via the firmware component config; configure their thresholds via NVS keys.
Helper scripts that mirror edge-module logic on the host (
FAQ
Does a settings change need reflashing?
Runtime settings are written over serial with the provisioning script. Firmware options need a rebuild.
What should I check on Windows?
The skill says to set UTF-8 environment variables before printing the help text, because it contains non-ASCII characters.
Can I see every provisioning option?
Yes. The skill says to run the script's help command for the full flag list.
Details
Original description by the author
Configure RuView — ESP32 sdkconfig variants, NVS provisioning, WiFi channel / MAC filter overrides (ADR-060), edge intelligence modules (ADR-041), sensing-server flags, multi-node mesh, and Cognitum Seed integration. Use when adjusting how a deployed RuView system behaves without changing code.
repo: ruvnet/RuView
Popularity
- GitHub stars
- 102k
- Ranking position
- #856
- License
- MIT
- Updated
- 11/2/2026
Comments
- …
More skills from this repository
AgentDB Advanced Features
102kShows your agent advanced AgentDB features, such as syncing databases across machines and combining vector search with metadata filters.
AgentDB Learning Plugins
102kLets your agent build and train learning plugins for AgentDB, using reinforcement learning methods that improve from past experience.
AgentDB Memory Patterns
102kLets your agent remember conversations and context across sessions, using AgentDB as its persistent memory store.
AgentDB Performance Optimization
102kShows your agent how to speed up AgentDB searches and reduce memory use, with compression, a fast search index and caching.
Similar skills
openclaw-update
394kHelps your agent update an existing OpenClaw Gateway, choosing the update method that fits how it was installed and keeping your session working.
diagnose-gateway
394kHelps your agent find out why your OpenClaw Gateway is failing by checking settings, channels, and ports without changing anything.
crabbox-apps
394kHelps your agent open and run an app on a temporary cloud machine, then show its view in your chat side panel.