Langsung ke konten
Skillpedia
Riset35k · #8277

performing-ot-network-security-assessment

Fungsinya

Tool ini membantu memeriksa keamanan jaringan industri (OT), seperti yang digunakan di pabrik dan pembangkit listrik. Tool ini menganalisis cara sistem saling berkomunikasi, mengidentifikasi risiko pada koneksi antara jaringan IT dan OT, serta memeriksa aturan keamanan.

Kapan dipakai

  • ✓Saat melakukan penilaian keamanan awal pada jaringan industri.
  • ✓Saat mengevaluasi keamanan setelah jaringan IT dan OT dihubungkan.
  • ✓Saat mempersiapkan audit keamanan industri.

Link skill

https://github.com/mukul975/Anthropic-Cybersecurity-Skills/blob/main/skills/performing-ot-network-security-assessment/SKILL.md

Salin lalu tempelkan ke AI Anda (Claude, ChatGPT, atau Cursor) dan minta AI mengikuti instruksinya.

Cara pakai

Cara paling mudah: salin pesan ini dan tempelkan ke AI Anda. AI akan membaca skill dan mengikuti instruksinya.

Pesan siap tempel

Gunakan skill ini untuk membantu saya: https://github.com/mukul975/Anthropic-Cybersecurity-Skills/blob/main/skills/performing-ot-network-security-assessment/SKILL.md Baca file SKILL.md di link tersebut dan ikuti instruksinya untuk tugas saya.
Mau AI Anda menemukan skill seperti ini sendiri?Pasang MCP Skillpedia gratis: cukup satu baris, dan AI mencari di antara 15.000+ skill sebelum tiap tugas.Pasang dalam 1 menit →

Contoh permintaan ke AI

“Analisis keamanan jaringan pembangkit listrik kami, dengan fokus pada koneksi antara sistem kendali dan jaringan perusahaan.”

5 skill baru setiap minggu. 1 menit baca.

Cara kerjanya

Tool ini menggunakan metode observasi pasif untuk memahami lalu lintas jaringan tanpa mengganggu operasional. Tool memetakan perangkat, protokol komunikasi, dan risiko keamanan.

Konten teknis (SKILL.md asli)

Teks asli dari pembuat, dalam bahasa Inggris, langsung dari GitHub.

Performing OT Network Security Assessment

When to Use

  • When conducting an initial security baseline of an OT/ICS environment for a new client
  • When evaluating the security posture of a facility after an IT/OT convergence initiative
  • When preparing for IEC 62443 or NERC CIP compliance audits
  • When assessing risk following a merger or acquisition involving industrial facilities
  • When investigating whether an OT network has been compromised or has unmonitored pathways to corporate IT

Do not use for IT-only network assessments without OT components, for application-layer vulnerability scanning of IT web applications (see performing-web-app-penetration-test), or for active exploitation of live OT systems without explicit authorization and safety controls in place.

Prerequisites

  • Written authorization from the asset owner and operations management for all assessment activities
  • Understanding of the Purdue Reference Model and IEC 62443 zone/conduit architecture
  • Passive network monitoring tools (Nozomi Guardian, Dragos Platform, or Wireshark with industrial protocol dissectors)
  • Access to network diagrams, firewall rule sets, and asset inventories (or the ability to perform passive discovery)
  • Safety briefing on the physical processes controlled by the OT systems under assessment

Workflow

Step 1: Establish Assessment Scope and Safety Boundaries

Define the scope based on the Purdue Reference Model levels and identify safety-critical systems that must not be actively scanned. OT assessments differ fundamentally from IT assessments because active scanning can crash PLCs, disrupt safety instrumented systems (SIS), and cause physical harm.

# OT Assessment Scope Definition
assessment:
  facility: "Chemical Processing Plant - Site Alpha"
  purdue_levels_in_scope:
    - level_0: "Physical process sensors and actuators (passive observation only)"
    - level_1: "PLCs, RTUs, safety controllers (passive only, no active scanning)"
    - level_2: "HMI stations, engineering workstations, historian (limited active with approval)"
    - level_3: "Site operations - OPC servers, application servers (active scanning permitted)"
    - level_3_5: "DMZ - data diodes, jump servers (active scanning permitted)"
    - level_4: "Enterprise IT connecting to OT (active scanning permitted)"

  safety_exclusions:
    - "Safety Instrumented Systems (SIS) - Triconex controllers"
    - "Emergency Shutdown (ESD) systems"
    - "Fire and Gas detection systems"
    - "Any Level 0/1 device during active production"

  authorized_activities:
    passive:
      - "Network traffic capture and analysis via SPAN ports"
      - "Industrial protocol deep packet inspection"
      - "Wireless spectrum analysis"
      - "Physical walkthrough and visual inspection"
    active_with_approval:
      - "Targeted Nmap scans of Level 2-4 systems during maintenance windows"
      - "Authentication testing on HMI and engineering workstations"
      - "Firewall rule verification between zones"
    prohibited:
      - "Active scanning of PLCs, RTUs, or SIS controllers"
      - "Fuzzing industrial protocols on live systems"
      - "Modifying PLC logic or firmware"

Step 2: Perform Passive Network Discovery and Asset Inventory

Deploy passive monitoring to map all devices, communication flows, and protocols on the OT network without sending any traffic that could disrupt operations.

#!/usr/bin/env python3
"""OT Network Passive Discovery and Asset Inventory Builder.

Uses pcap captures from SPAN ports to identify OT assets, protocols,
and communication patterns without active scanning.
"""

import json
import sys
from collections import defaultdict
from datetime import datetime

try:
    from scapy.all import rdpcap, IP, TCP, UDP
    from scapy.contrib.modbus import ModbusADURequest, ModbusADUResponse
except ImportError:
    print("Install scapy: pip install scapy")
    sys.exit(1)

# Industrial protocol port mappings
OT_PROTOCOL_PORTS = {
    502: "Modbus/TCP",
    102: "S7comm (Siemens)",
    44818: "EtherNet/IP (CIP)",
    2222: "EtherNet/IP (implicit)",
    4840: "OPC UA",
    20000: "DNP3",
    47808: "BACnet",
    1911: "Niagara Fox",
    789: "Crimson v3 (Red Lion)",
    2404: "IEC 60870-5-104",
    18245: "GE SRTP",
    5094: "HART-IP",
}

PURDUE_LEVEL_RANGES = {
    "Level 0-1 (Field Devices)": ["10.10.0.0/16", "192.168.10.0/24"],
    "Level 2 (Control Systems)": ["10.20.0.0/16", "192.168.20.0/24"],

…
Pertanyaan umum

Apa itu jaringan OT?

Jaringan OT (Operational Technology) mengendalikan peralatan fisik di lingkungan seperti pabrik, pembangkit listrik, dan infrastruktur kritis. Jaringan ini berbeda dengan jaringan IT (Information Technology) yang digunakan di kantor.

Mengapa keamanan jaringan OT penting?

Pelanggaran keamanan di jaringan OT dapat menyebabkan produksi terhenti, merusak peralatan fisik, bahkan membahayakan keselamatan manusia.

Apakah tool ini bisa menyebabkan masalah di jaringan?

Tidak. Tool ini dirancang bersifat pasif, artinya hanya mengamati lalu lintas data tanpa mengirim perintah yang dapat memengaruhi sistem industri.

Detail

Deskripsi asli dari pembuat

This skill covers conducting comprehensive security assessments of Operational Technology (OT) networks including SCADA systems, DCS architectures, and industrial control system communication paths. It addresses the Purdue Reference Model layers, identifies IT/OT convergence risks, evaluates firewall rules between zones, and maps industrial protocol traffic (Modbus, DNP3, OPC UA, EtherNet/IP) to d

repo: mukul975/Anthropic-Cybersecurity-Skills

Popularitas

Bintang GitHub
35k
Peringkat
#8277
Lisensi
Apache-2.0
Diperbarui
31/8/2026

Apakah skill ini berguna?

0

Masuk untuk memberi suara.

Komentar

  • …

Skill lain dari repositori ini

Skill serupa