performing-power-grid-cybersecurity-assessment
Fungsinya
Alat ini membantu memeriksa keamanan siber sistem jaringan listrik, seperti pembangkit listrik dan gardu induk. Alat ini menganalisis apakah peralatan terlindungi dari serangan dan mengikuti aturan keamanan.
Kapan dipakai
- ✓Untuk memeriksa keamanan gardu induk listrik secara berkala.
- ✓Saat menilai keamanan sistem kendali tenaga listrik.
- ✓Untuk memastikan aturan keamanan (NERC CIP) sudah diikuti.
Link skill
https://github.com/mukul975/Anthropic-Cybersecurity-Skills/blob/main/skills/performing-power-grid-cybersecurity-assessment/SKILL.mdSalin lalu tempelkan ke AI Anda (Claude, ChatGPT, atau Cursor) dan minta AI mengikuti instruksinya.
Cara pakai
Cara paling mudah: salin pesan ini dan tempelkan ke AI Anda. AI akan membaca skill dan mengikuti instruksinya.
Pesan siap tempel
Untuk Claude Code, Codex, atau Cursor: jalankan di folder proyek, lalu skill langsung terpasang.
Unduh SKILL.md lalu taruh di folder skill agen Anda.
Contoh permintaan ke AI
“Lakukan penilaian keamanan siber untuk gardu induk X, dengan fokus pada protokol IEC 61850.”
5 skill baru setiap minggu. 1 menit baca.
Cara kerjanya
Alat ini memetakan jaringan listrik, mengidentifikasi sistem dan protokol yang digunakan, lalu memeriksa kerentanan yang sudah dikenal atau konfigurasi yang tidak aman.
Konten teknis (SKILL.md asli)
Teks asli dari pembuat, dalam bahasa Inggris, langsung dari GitHub.
Performing Power Grid Cybersecurity Assessment
When to Use
- When conducting periodic cybersecurity assessments of power grid facilities per NERC CIP requirements
- When assessing substation automation systems using IEC 61850 GOOSE and MMS protocols
- When evaluating the security of an Energy Management System (EMS) or SCADA control center
- When assessing synchrophasor (PMU) networks and wide-area monitoring systems
- When preparing for regional entity compliance audits or internal security reviews
Do not use for non-BES systems below NERC registration thresholds, for general OT assessment without power grid specifics (see performing-ot-network-security-assessment), or for physical security assessment of generation facilities without cyber scope.
Prerequisites
- Understanding of electric power grid architecture (generation, transmission, distribution)
- Familiarity with NERC CIP standards and BES Cyber System categorization
- Knowledge of power grid protocols (IEC 61850, IEC 60870-5-104, DNP3, ICCP/TASE.2)
- Passive monitoring tools for substation network traffic analysis
- Access to EMS/SCADA architecture documentation and network diagrams
Workflow
Step 1: Map Power Grid Cyber Architecture
Identify and document all cyber systems supporting grid operations including EMS, SCADA, substation automation, and communication infrastructure.
# Power Grid Cyber Architecture Assessment
facility_type: "Regional Transmission Organization Control Center"
ems_systems:
primary_ems:
vendor: "GE Grid Solutions"
product: "EMS/SCADA (formerly XA/21)"
functions:
- "State estimation"
- "Automatic generation control (AGC)"
- "Security-constrained economic dispatch"
- "Contingency analysis"
protocols:
- "ICCP/TASE.2 (inter-control center)"
- "DNP3 (substation RTU polling)"
- "IEC 60870-5-104 (substation polling)"
backup_control_center:
location: "Geographically diverse backup site"
sync_method: "Real-time database mirroring"
switchover_time: "< 5 minutes"
substation_automation:
count: 145
system_types:
- vendor: "ABB"
product: "RTU560"
protocol: "DNP3 over TCP/IP"
count: 85
- vendor: "SEL"
product: "SEL-3530 RTAC"
protocol: "IEC 61850 MMS + GOOSE"
count: 40
- vendor: "Siemens"
product: "SICAM A8000"
protocol: "IEC 60870-5-104"
count: 20
communications:
primary: "MPLS WAN (carrier-provided)"
backup: "Licensed microwave radio"
last_mile: "Fiber optic to substation"
synchrophasor_network:
pmu_count: 75
pdc: "GE PDC (Phasor Data Concentrator)"
communication: "IEEE C37.118.2 over dedicated network"
data_rate: "30-60 samples per second"
Step 2: Assess Substation Automation Security
Evaluate IEC 61850-based substation automation for protocol security, access controls, and network segmentation.
#!/usr/bin/env python3
"""Power Grid Substation Security Assessor.
Evaluates security of IEC 61850-based substation automation
systems including GOOSE messaging, MMS client/server, and
network architecture.
"""
import json
import sys
from dataclasses import dataclass, field, asdict
from datetime import datetime
@dataclass
class SubstationFinding:
finding_id: str
severity: str
category: str
title: str
description: str
affected_systems: list
nerc_cip_ref: str
iec_62351_ref: str
remediation: str
class SubstationAssessment:
"""Assesses cybersecurity of substation automation systems."""
def __init__(self, substation_name):
self.name = substation_name
self.findings = []
self.counter = 1
def assess_iec61850_security(self, config):
"""Assess IEC 61850 protocol security."""
# GOOSE message authentication
if not config.get("goose_authentication"):
self.findings.append(SubstationFinding(
finding_id=f"SUB-{self.counter:03d}",
severity="critical",
category="Protocol Security",
title="IEC 61850 GOOSE Messages Lack Authentication",
description=(
"GOOSE messages used for protection signaling between IEDs "
"are not authenticated. An attacker on the station bus could "
"inject false trip/close commands to circuit breakers."
),
…
Pertanyaan umum
Apa itu NERC CIP dan IEC 61850?
Keduanya adalah kumpulan aturan dan standar untuk memastikan keamanan siber sistem tenaga listrik.
Apa itu EMS dan SCADA?
Keduanya adalah sistem yang digunakan untuk mengendalikan dan memantau jaringan listrik secara real-time.
Apa itu serangan seperti Industroyer/CrashOverride?
Ini adalah contoh serangan siber yang bertujuan mengganggu pasokan listrik.
Detail
Deskripsi asli dari pembuat
Conduct cybersecurity assessments of power grid infrastructure spanning generation, transmission substations, distribution, and EMS control centers, covering NERC CIP compliance verification, IEC 61850 (GOOSE/MMS) substation protocol analysis, and synchrophasor (PMU) network security against threats like Industroyer/CrashOverride. Use for periodic NERC CIP assessments, substation automation or EMS
Popularitas
- Bintang GitHub
- 35k
- Peringkat
- #8286
- Lisensi
- Apache-2.0
- Diperbarui
- 31/8/2026
Komentar
- …
Skill lain dari repositori ini
abusing-dpapi-for-credential-access
35kMemberi agent AI Anda instruksi siap pakai untuk tugas tertentu, sehingga hasilnya lebih baik dan pengerjaannya lebih cepat.
abusing-shadow-credentials-for-privesc
35kMengajarkan agent AI Anda menulis teks yang jelas dan terstruktur dengan baik.
achieving-cmmc-level-2-compliance
35kMembantu agent Anda menyiapkan lingkungan untuk kepatuhan CMMC Level 2. Skill ini menerapkan persyaratan keamanan dan mengelola dokumentasi yang diperlukan.
acquiring-disk-image-with-dd-and-dcfldd
35kMembantu agent Anda membuat salinan persis dari hard drive. Berguna untuk memastikan tidak ada informasi yang hilang atau berubah selama investigasi.
Skill serupa
reverse-engineer-anything
422kMembantu agent Anda memeriksa aplikasi dan paket yang sudah dirilis untuk menjelaskan fitur, membandingkan versi, atau memandu pembangunan ulang dengan alat REA.
1password
394kMembantu agent Anda mengatur CLI 1Password, masuk, serta membaca atau menyisipkan rahasia tanpa menampilkan nilainya di chat.
healthcheck
394kMembantu agent Anda mengaudit komputer atau server OpenClaw dari risiko keamanan seperti SSH, firewall, pembaruan, dan cadangan, lalu menyarankan perbaikan aman.