FDA MedTech Compliance Auditor
Overview
This skill assists a qualified medical-device quality/regulatory reviewer; it does not confer auditor certification or FDA approval. It focuses on Software as a Medical Device (SaMD) and traditional medical equipment regulations, including 21 CFR Part 820 (current QMSR; historical QSR requirements must be dated), IEC 62304 (Software Lifecycle), ISO 13485, and ISO 14971 (Risk Management).
When to Use This Skill
- Use when reviewing Software Validation Protocols for Medical Devices.
- Use when auditing a Design History File (DHF) for a software-based diagnostic tool.
- Use when ensuring IT infrastructure meets 21 CFR Part 11 requirements for electronic records.
- Use when preparing a CAPA (Corrective and Preventive Action) for a software defect.
How It Works
- Activate the Skill: Mention
@fda-medtech-compliance-auditorand provide the document you wish to review. - Specify the Standard: State whether the focus is on Part 820, Part 11, ISO 13485, ISO 14971, or IEC 62304.
- Receive Findings: The AI outputs specific audit findings categorized by severity (Major, Minor, Opportunity for Improvement) with regulatory citations.
- Correction Guidance: Get actionable steps to resolve each finding and strengthen your audit readiness.
Examples
Example 1: CAPA Root Cause Review
Scenario: A CAPA was opened for a software defect in a Class II device. The documented root cause is “developer error — unclear requirements.” The corrective action is developer retraining.
Finding:
FDA AUDIT FINDING
Severity: Major
Reference check: determine applicable current QMSR/ISO 13485 CAPA requirements; legacy 820.100(a)(2) is historical, not a current standalone citation
Analysis:
"Developer error" is a symptom, not a root cause. Retraining alone does not demonstrate that recurrence risk was addressed.
The record is insufficient to establish the true root cause; investigate
requirements, process controls and human factors without preselecting a conclusion.
Required Actions:
1. Perform a 5-Whys or Fishbone analysis targeting the requirements
gathering and review process.
2. Update the SRS (Software Requirements Specification) and the
corresponding process SOP.
3. Document an effectiveness check with a measurable criterion
(e.g., zero requirements-related defects in next 3 releases).
4. Do not close the CAPA on retraining alone.
Best Practices
- ✅ Do: Provide exact wording from SOPs, risk tables, or validation plans for the most accurate review.
- ✅ Do: Expect strict interpretations — the goal is to find weaknesses before a real inspector does.
- ❌ Don't: Forget to link every software defect to a clinical risk item in your ISO 14971 risk file.
- ❌ Don't: Assume "we tested it and it works" satisfies IEC 62304 software verification requirements.
Limitations
- FDA’s QMSR became effective February 2, 2026 and incorporates ISO 13485:2016. Determine rule date, device/jurisdiction applicability and exact controlled standard editions before citing clauses; do not reuse a superseded Part820.100 citation as current law.
- This is review assistance, not certification, clinical safety proof or legal advice. Findings/grades require actual evidence and qualified assessment. Never authorize product release, change a risk file/CAPA, suppress a defect or claim FDA compliance from the template; protect patient/device confidential data.
- Do not treat the output as a substitute for environment-specific validation, testing, or expert review.
- Stop and ask for clarification if required inputs, permissions, safety boundaries, or success criteria are missing.
常见问题
DHF、IEC 62304、21 CFR Part 820、ISO 13485 和 ISO 14971 分别是什么?
这些都是标准或法规,规定了医疗器械(尤其是软件)应如何开发、测试和管理,以确保安全和质量。
AI 能批准我的医疗器械或提供法律建议吗?
不能。这个工具只用于辅助审查,不能替代合格专家的评估,也不提供监管审批或法律建议。
如果 AI 发现问题,会怎样?
AI 会列出发现的问题,并按严重程度分类(主要、次要、改进机会),同时附上相关标准的引用。它还会为每个问题提供修正建议,帮助你提高审核准备度。
详情
作者的原始描述
Expert AI auditor for Medical Device (SaMD) compliance, IEC 62304, and 21 CFR Part 820. Reviews DHFs, technical files, and software validation.
热度
- GitHub 星标
- 48k
- 排名
- #4603
- 许可证
- MIT
- 更新时间
- 2026/10/15
评论
- …
同一仓库的更多技能
00-andruia-consultant
48k帮你的智能体启动或改进 AI 项目。它可以分析代码、推荐工具,并用西班牙语制定行动计划。
007
48k让你的智能体执行安全审计和威胁建模。它有助于保护项目免受攻击和漏洞的威胁。
10-andruia-skill-smith
48k帮你的智能体创建或改进 AI 工具。它可以定义工具的工作方式、编写文档,并验证其结构。
20-andruia-niche-intelligence
48k让你的智能体创建某个特定行业的摘要。它有助于借助可靠的信息来源,了解项目的背景、规则、使用模式和风险。