Risk Management Specialist
ISO 14971:2019 risk management implementation throughout the medical device lifecycle.
Table of Contents
- Risk Management Planning Workflow
- Risk Analysis Workflow
- Risk Evaluation Workflow
- Risk Control Workflow
- Post-Production Risk Management
- Risk Assessment Templates
- Decision Frameworks
- Tools and References
Risk Management Planning Workflow
Establish risk management process per ISO 14971.
Workflow: Create Risk Management Plan
- Define scope of risk management activities:
- Medical device identification
- Lifecycle stages covered
- Applicable standards and regulations
- Establish risk acceptability criteria:
- Define probability categories (P1-P5)
- Define severity categories (S1-S5)
- Create risk matrix with acceptance thresholds
- Assign responsibilities:
- Risk management lead
- Subject matter experts
- Approval authorities
- Define verification activities:
- Methods for control verification
- Acceptance criteria
- Plan production and post-production activities:
- Information sources
- Review triggers
- Update procedures
- Obtain plan approval
- Establish risk management file
- Validation: Plan approved; acceptability criteria defined; responsibilities assigned; file established
Risk Management Plan Content
| Section | Content | Evidence |
|---|---|---|
| Scope | Device and lifecycle coverage | Scope statement |
| Criteria | Risk acceptability matrix | Risk matrix document |
| Responsibilities | Roles and authorities | RACI chart |
| Verification | Methods and acceptance | Verification plan |
| Production/Post-Production | Monitoring activities | Surveillance plan |
Risk Acceptability Matrix (5x5)
| Probability \ Severity | Negligible | Minor | Serious | Critical | Catastrophic |
|---|---|---|---|---|---|
| Frequent (P5) | Medium | High | High | Unacceptable | Unacceptable |
| Probable (P4) | Medium | Medium | High | High | Unacceptable |
| Occasional (P3) | Low | Medium | Medium | High | High |
| Remote (P2) | Low | Low | Medium | Medium | High |
| Improbable (P1) | Low | Low | Low | Medium | Medium |
Risk Level Actions
| Level | Acceptable | Action Required |
|---|---|---|
| Low | Yes | Document and accept; still reduce as far as possible (EU MDR) |
| Medium | After reduction AFAP | Reduce as far as possible; document why further reduction is impossible |
| High | After reduction AFAP | Reduction required; demonstrate all further options exhausted |
| Unacceptable | No | Design change mandatory |
EU MDR — AFAP, not ALARP: For CE-marked devices, risks must be reduced as far as possible (AFAP) without economic considerations (MDR Annex I, GSPR 1–4; EN ISO 14971:2019/A11:2021 Z-annexes deviation). ALARP ("as low as reasonably practicable"), which permits cost-benefit weighing in acceptability decisions, is not an acceptable criterion under the EU MDR — a notified body will flag it. ISO 14971:2019 itself removed ALARP from the normative text. ALARP may persist in some non-EU jurisdictions (e.g., the UK HSE tradition); if used outside the EU, flag the deviation from EU requirements explicitly.
Risk Analysis Workflow
Identify hazards and estimate risks systematically.
Workflow: Conduct Risk Analysis
- Define intended use and reasonably foreseeable misuse:
- Medical indication
- Patient population
- User population
- Use environment
- Select analysis method(s):
- FMEA for component/function analysis
- FTA for system-level analysis
- HAZOP for process deviations
- Use Error Analysis for user interaction
- Identify hazards by category:
- Energy hazards (electrical, mechanical, thermal)
- Biological hazards (bioburden, biocompatibility)
- Chemical hazards (residues, leachables)
- Operational hazards (software, use errors)
- Determine hazardous situations:
- Sequence of events
- Foreseeable misuse scenarios
- Single fault conditions
- Estimate probability of harm (P1-P5)
- Estimate severity of harm (S1-S5)
- Document in hazard analysis worksheet
常见问题
它遵循哪项标准?
它遵循 ISO 14971:2019 进行医疗器械风险管理。
它涵盖产品售出后的风险吗?
涵盖,这项技能包括上市后的风险管理。
它会设置风险矩阵吗?
会的,它会设定概率和严重度的类别,以及带有可接受阈值的矩阵。
详情
作者的原始描述
Use for ISO 14971 medical device risk management: hazard analysis, FMEA, fault trees, risk controls, benefit-risk or residual risk. Runs fmea_analyzer.py and risk_matrix_calculator.py.
热度
- GitHub 星标
- 29k
- 排名
- #9742
- 许可证
- MIT
- 更新时间
- 2026/11/2
评论
- …
同一仓库的更多技能
agent-launcher-orchestrator
29k帮你的智能体从一个清晰的目标出发,逐步规划、构建、测试并定时运行你自己账户中的 Claude 托管智能体。
grade-iterate
29k让你的智能体按评分标准为托管 AI 智能体的工作打分,并在固定的轮次内改进,因此它永远不会无限循环。
interview
29k让你的智能体就一个 AI 智能体的想法对你进行访谈,并在任何上线之前,把你的回答整理成一份简单的构建计划。
run-without-you
29k帮你的智能体设置托管 AI 智能体,使其按计划或在某个事件发生时运行,并在启动前检查定时设置。