detecting-modbus-command-injection-attacks
Has your agent detect command injection in Modbus TCP/RTU environments. Monitors unauthorized writes and anomalous function codes in industrial networks (ICS/SCADA).
What it does
This system monitors Modbus network traffic to identify attack attempts that try to improperly control industrial devices. It looks for suspicious commands and deviations from normal behavior.
When to use it
- ✓When installing security systems for industrial networks (SCADA/ICS).
- ✓When investigating unauthorized changes to industrial equipment (PLCs).
- ✓When responding to known attacks targeting industrial control systems.
Example of what to ask your AI
“Check for suspicious activity on the Modbus network.”
Want more? Open the sections below.
How to use
The easiest way: copy the message below and paste it into Claude, ChatGPT, Cursor or any AI. It reads the skill and follows the instructions.
Skill link
Ready-to-paste message
How it works
It compares Modbus network traffic against a record of normal communication. If it finds unusual commands, disallowed writes, or strange communication patterns, it raises an alert.
Installation
Easiest way: copy the skill link and paste it into Claude, ChatGPT or Cursor asking it to follow the instructions.
In the terminal (Claude Code, Codex, Cursor), in your project folder:
npx skills add mukul975/Anthropic-Cybersecurity-Skills --skill detecting-modbus-command-injection-attacksOr download just the file:
curl -L https://raw.githubusercontent.com/mukul975/Anthropic-Cybersecurity-Skills/main/skills/detecting-modbus-command-injection-attacks/SKILL.md -o SKILL.mdTechnical content (original SKILL.md)
Original text by the author, straight from GitHub.
Detecting Modbus Command Injection Attacks
When to Use
- When deploying intrusion detection for environments using Modbus TCP (port 502) or Modbus RTU
- When investigating suspected unauthorized modifications to PLC registers or coils
- When building detection analytics for OT SOC monitoring Modbus-heavy environments
- When responding to FrostyGoop-style attacks that leverage Modbus TCP for operational impact
- When performing baseline validation after a suspected compromise of a Modbus master
Do not use for detecting attacks on non-Modbus protocols (see detecting-dnp3-protocol-anomalies for DNP3), for general IT network intrusion detection, or for Modbus device configuration (see performing-ot-vulnerability-scanning-safely).
Prerequisites
- Network SPAN/TAP on the segment carrying Modbus TCP traffic (typically port 502)
- Baseline of normal Modbus communication patterns (masters, slaves, function codes, register ranges, polling intervals)
- Suricata, Zeek, or commercial OT IDS deployed with Modbus protocol parsers enabled
- Understanding of Modbus function codes used in the environment (read vs write operations)
- Access to PLC programming documentation to validate expected register ranges
Workflow
Step 1: Build Modbus Communication Baseline
Capture and analyze normal Modbus traffic to establish what constitutes legitimate communication patterns.
#!/usr/bin/env python3
"""Modbus Command Injection Detector.
Monitors Modbus TCP traffic for unauthorized write operations, anomalous
function codes, and deviations from established communication baselines.
Detects attacks like FrostyGoop that use Modbus TCP for operational impact.
"""
import json
import struct
import sys
import time
from collections import defaultdict
from datetime import datetime
from typing import Dict, List, Optional, Set, Tuple
try:
from scapy.all import sniff, IP, TCP
except ImportError:
print("Install scapy: pip install scapy")
sys.exit(1)
# Modbus function code definitions
MODBUS_READ_FUNCTIONS = {1, 2, 3, 4}
MODBUS_WRITE_FUNCTIONS = {5, 6, 15, 16}
MODBUS_DIAGNOSTIC_FUNCTIONS = {8, 17, 43}
MODBUS_FUNC_NAMES = {
1: "Read Coils", 2: "Read Discrete Inputs",
3: "Read Holding Registers", 4: "Read Input Registers",
5: "Write Single Coil", 6: "Write Single Register",
8: "Diagnostics", 15: "Write Multiple Coils",
16: "Write Multiple Registers", 17: "Report Slave ID",
22: "Mask Write Register", 23: "Read/Write Multiple Registers",
43: "Encapsulated Interface Transport",
}
class ModbusAlert:
"""Represents a detected Modbus anomaly."""
def __init__(self, severity: str, alert_type: str, src_ip: str,
dst_ip: str, unit_id: int, func_code: int,
description: str, mitre_technique: str = ""):
self.timestamp = datetime.now().isoformat()
self.severity = severity
self.alert_type = alert_type
self.src_ip = src_ip
self.dst_ip = dst_ip
self.unit_id = unit_id
self.func_code = func_code
self.func_name = MODBUS_FUNC_NAMES.get(func_code, f"Unknown FC {func_code}")
self.description = description
self.mitre_technique = mitre_technique
def __str__(self):
return (
f"[{self.severity}] {self.alert_type} | {self.src_ip} -> {self.dst_ip} "
f"| Unit {self.unit_id} | {self.func_name} | {self.description}"
)
class ModbusInjectionDetector:
"""Detects Modbus command injection attacks."""
def __init__(self, baseline_file: Optional[str] = None):
self.alerts: List[ModbusAlert] = []
self.packet_count = 0
self.modbus_count = 0
# Baseline data
self.authorized_masters: Set[str] = set()
self.authorized_pairs: Set[Tuple[str, str]] = set()
self.allowed_write_sources: Set[str] = set()
self.allowed_function_codes: Dict[str, Set[int]] = defaultdict(set)
self.allowed_register_ranges: Dict[str, List[Tuple[int, int]]] = defaultdict(list)
self.polling_intervals: Dict[str, float] = {}
self.last_seen: Dict[str, float] = {}
# Counters for rate detection
self.write_counts: Dict[str, List[float]] = defaultdict(list)
if baseline_file:
self.load_baseline(baseline_file)
def load_baseline(self, filepath: str):
"""Load established Modbus communication baseline."""
with open(filepath, "r") as f:
…
FAQ
What is Modbus?
Modbus is a communication protocol used in industrial systems to allow devices (like sensors and controllers) to talk to each other.
What is 'command injection'?
It's a type of attack where an attacker tries to make a system execute commands it shouldn't, often to take control or cause damage.
What are PLCs?
PLCs (Programmable Logic Controllers) are computers used to automate processes in industrial environments, such as factories.
Details
Original description by the author
Detect command injection against Modbus TCP/RTU in ICS/SCADA environments by monitoring unauthorized writes, anomalous function codes, malformed frames, and deviations from communication baselines using ICS-aware IDS and deep packet inspection. Use when deploying IDS for Modbus OT networks, investigating unauthorized PLC register/coil changes, or responding to FrostyGoop-style Modbus attacks.
Popularity
- GitHub stars
- 35k
- Ranking position
- #5687
- License
- Apache-2.0
- Updated
- 8/31/2026
Comments
- …
More skills from this repository
abusing-dpapi-for-credential-access
Gives your AI agent ready-made instructions for a specific task, so it does it better and faster.
mukul975/Anthropic-Cybersecurity-Skills
abusing-shadow-credentials-for-privesc
Teaches your AI agent to write clear, well-structured text.
mukul975/Anthropic-Cybersecurity-Skills
achieving-cmmc-level-2-compliance
Helps your agent prepare an environment for CMMC Level 2 compliance. It implements security requirements and manages necessary documentation.
mukul975/Anthropic-Cybersecurity-Skills
acquiring-disk-image-with-dd-and-dcfldd
Helps your agent create exact copies of hard drives. This is useful for ensuring no information is lost or altered during investigations.
mukul975/Anthropic-Cybersecurity-Skills
Similar skills
agent-architecture-audit
Makes your agent check if everything is working correctly. It finds and fixes problems in AI systems, ensuring they perform as expected.
affaan-m/ECC
agent-eval
Helps your agent compare different AI coding tools. It measures which one is faster, cheaper, and more reliable for specific tasks.
affaan-m/ECC
agent-harness-construction
Makes your agent better understand how to perform tasks. It optimizes the tools and instructions the agent uses to increase its chances of success.
affaan-m/ECC