fda-medtech-compliance-auditor
Audits medical device compliance with FDA regulations. Analyzes documentation and software validation, ensuring safety and quality.
What it does
This AI assistant helps review medical device documents to ensure they follow safety and quality rules set by regulatory bodies like the FDA. It checks if medical software and equipment comply with specific standards.
When to use it
- ✓When reviewing software testing plans for medical devices.
- ✓When auditing the documentation for a medical diagnostic app.
- ✓When checking if IT infrastructure meets electronic records requirements.
Example of what to ask your AI
“Review this software validation document against the IEC 62304 standard.”
Want more? Open the sections below.
How to use
The easiest way: copy the message below and paste it into Claude, ChatGPT, Cursor or any AI. It reads the skill and follows the instructions.
Skill link
Ready-to-paste message
How it works
You mention the assistant's name and provide the document you want reviewed. Then, you specify which regulatory standard to focus on. The AI will present findings, indicating their severity and where they relate to the rules, along with suggestions for correction.
Installation
Easiest way: copy the skill link and paste it into Claude, ChatGPT or Cursor asking it to follow the instructions.
In the terminal (Claude Code, Codex, Cursor), in your project folder:
npx skills add sickn33/agentic-awesome-skills --skill fda-medtech-compliance-auditorOr download just the file:
curl -L https://raw.githubusercontent.com/sickn33/agentic-awesome-skills/main/plugins/agentic-awesome-skills-claude/skills/fda-medtech-compliance-auditor/SKILL.md -o SKILL.mdTechnical content (original SKILL.md)
Original text by the author, straight from GitHub.
FDA MedTech Compliance Auditor
Overview
This skill assists a qualified medical-device quality/regulatory reviewer; it does not confer auditor certification or FDA approval. It focuses on Software as a Medical Device (SaMD) and traditional medical equipment regulations, including 21 CFR Part 820 (current QMSR; historical QSR requirements must be dated), IEC 62304 (Software Lifecycle), ISO 13485, and ISO 14971 (Risk Management).
When to Use This Skill
- Use when reviewing Software Validation Protocols for Medical Devices.
- Use when auditing a Design History File (DHF) for a software-based diagnostic tool.
- Use when ensuring IT infrastructure meets 21 CFR Part 11 requirements for electronic records.
- Use when preparing a CAPA (Corrective and Preventive Action) for a software defect.
How It Works
- Activate the Skill: Mention
@fda-medtech-compliance-auditorand provide the document you wish to review. - Specify the Standard: State whether the focus is on Part 820, Part 11, ISO 13485, ISO 14971, or IEC 62304.
- Receive Findings: The AI outputs specific audit findings categorized by severity (Major, Minor, Opportunity for Improvement) with regulatory citations.
- Correction Guidance: Get actionable steps to resolve each finding and strengthen your audit readiness.
Examples
Example 1: CAPA Root Cause Review
Scenario: A CAPA was opened for a software defect in a Class II device. The documented root cause is “developer error — unclear requirements.” The corrective action is developer retraining.
Finding:
FDA AUDIT FINDING
Severity: Major
Reference check: determine applicable current QMSR/ISO 13485 CAPA requirements; legacy 820.100(a)(2) is historical, not a current standalone citation
Analysis:
"Developer error" is a symptom, not a root cause. Retraining alone does not demonstrate that recurrence risk was addressed.
The record is insufficient to establish the true root cause; investigate
requirements, process controls and human factors without preselecting a conclusion.
Required Actions:
1. Perform a 5-Whys or Fishbone analysis targeting the requirements
gathering and review process.
2. Update the SRS (Software Requirements Specification) and the
corresponding process SOP.
3. Document an effectiveness check with a measurable criterion
(e.g., zero requirements-related defects in next 3 releases).
4. Do not close the CAPA on retraining alone.
Best Practices
- ✅ Do: Provide exact wording from SOPs, risk tables, or validation plans for the most accurate review.
- ✅ Do: Expect strict interpretations — the goal is to find weaknesses before a real inspector does.
- ❌ Don't: Forget to link every software defect to a clinical risk item in your ISO 14971 risk file.
- ❌ Don't: Assume "we tested it and it works" satisfies IEC 62304 software verification requirements.
Limitations
- FDA’s QMSR became effective February 2, 2026 and incorporates ISO 13485:2016. Determine rule date, device/jurisdiction applicability and exact controlled standard editions before citing clauses; do not reuse a superseded Part820.100 citation as current law.
- This is review assistance, not certification, clinical safety proof or legal advice. Findings/grades require actual evidence and qualified assessment. Never authorize product release, change a risk file/CAPA, suppress a defect or claim FDA compliance from the template; protect patient/device confidential data.
- Do not treat the output as a substitute for environment-specific validation, testing, or expert review.
- Stop and ask for clarification if required inputs, permissions, safety boundaries, or success criteria are missing.
FAQ
What are DHF, IEC 62304, 21 CFR Part 820, ISO 13485, and ISO 14971?
These are standards and regulations that define how medical devices, especially software, should be developed, tested, and managed to ensure safety and quality.
Can the AI approve my medical device or give legal advice?
No. This tool is only for review assistance. It does not replace assessment by a qualified expert, nor does it offer regulatory approval or legal advice.
What happens if the AI finds an issue?
The AI will list the findings, categorized by severity (Major, Minor, Opportunity for Improvement), with references to the standards. It will also offer suggested actions to correct each issue and improve audit readiness.
Details
Original description by the author
Expert AI auditor for Medical Device (SaMD) compliance, IEC 62304, and 21 CFR Part 820. Reviews DHFs, technical files, and software validation.
Popularity
- GitHub stars
- 48k
- Ranking position
- #2989
- License
- MIT
- Updated
- 10/15/2026
Comments
- …
More skills from this repository
00-andruia-consultant
Helps your agent start or improve AI projects. It analyzes code, suggests tools, and creates action plans in Spanish.
sickn33/agentic-awesome-skills
007
Lets your agent perform security audits and threat modeling. It's useful for protecting projects against attacks and vulnerabilities.
sickn33/agentic-awesome-skills
10-andruia-skill-smith
Helps your agent create or improve AI tools. It defines how tools work, writes documentation, and validates the structure.
sickn33/agentic-awesome-skills
20-andruia-niche-intelligence
Lets your agent create a summary about a specific industry. It's useful for understanding the context, rules, usage patterns, and risks of a project, using reliable sources.
sickn33/agentic-awesome-skills
Similar skills
architecture-decision-records
Has your agent record important project structure decisions. It helps to understand the reasoning behind choices and maintain a clear history of changes.
affaan-m/ECC
code-tour
Lets your agent create step-by-step code walkthroughs with exact file and line anchors. It's useful for project introductions, code explanations, or change reviews. Helps understand how a system works.
affaan-m/ECC
codebase-onboarding
Helps your agent analyze unfamiliar code and create an onboarding guide. It includes an architecture map, entry points, and conventions. Ideal for starting on a new project.
affaan-m/ECC